
TROUBLE- SHOOTING
Continued
OBSERVED | POSSIBLE |
|
|
| |
PROBLEM | CAUSE | REMEDY |
| ||
|
|
|
|
|
|
Delayed ignition of | 1. | Manifold pressure is | 1. | Contact local propane |
|
burner. |
| too low. |
| gas company. |
|
| 2. | Burner orifice is | 2. | Clean burner (see |
|
|
| clogged. |
| Cleaning and Mainte- |
|
|
|
|
| nance, page 26) or |
|
|
|
|
| replace burner orifice |
|
|
|
|
| (see Changing Burner |
|
|
|
|
| Orifice, page 34). |
|
|
|
|
|
|
|
Burner backfiring | 1. | Burner orifice is | 1. | Clean burner (see |
|
during combustion. |
| clogged or damaged. |
| Cleaning and Mainte- |
|
|
|
|
| nance, page 26) or |
|
|
|
|
| replace burner orifice |
|
|
|
|
| (see Changing Burner |
|
|
|
|
| Orifice, page 34). |
|
| 2. | Burner damaged. | 2. | Replace burner. |
|
| 3. | Gas regulator defective. | 3. | Replace control valve. |
|
| 4. | Delayed ignition. | 4. | See above. |
|
|
|
|
|
|
|
Yellow flame during | 1. | Not enough air. | 1. | Check burner for dirt |
|
burner combustion |
|
|
| and debris. If found, |
|
|
|
|
| clean burner (see |
|
|
|
|
| Cleaning and Mainte- |
|
|
|
|
| nance, page 26). |
|
| 2. | Gas regulator defective. | 2. | Replace control valve. |
|
|
|
|
|
|
|
Flame lifting during | 1. | Burner orifice is | 1. | Clean burner (see |
|
combustion. |
| clogged or damaged. |
| Cleaning and Mainte- |
|
|
|
|
| nance, page 26) or |
|
|
|
|
| replace burner orifice |
|
|
|
|
| (see Changing Burner |
|
|
|
|
| Orifice, page 34). |
|
| 2. | Manifold pressure too | 2. | Replace control valve |
|
|
| high/defective gas |
| (see Removing Control |
|
|
| regulator |
| Valve and Burner Tube, |
|
|
|
|
| page 32). |
|
|
|
|
|
| |
Slight smoke or odor | 1. Residues from manu- | 1. | Problem will stop after a |
| |
during initial opera- |
| facturing processes. |
| few hours of operation. |
|
tion. |
|
|
|
|
|
Continued
100791
29