Desa GVR65PA, GVR50PA, GVR65BPA, GVR35PA, GVR50BPA Installing Glass Panel, For Radiant Models Only

Page 15

INSTALLING

INSTALLING GLASS PANEL

HEATER

For Radiant Models Only

1. Locate the glass panel package inside the back of the heater.

Continued

 

 

 

WARNING ICONG 001CAUTION

 

 

Before installing glass panels, inspect the edges. If you notice any chips or cracks, do not install. If the surface on either side is deeply scratched, do not install. If these conditions exist, contact your Vanguard Dealer for replacement glass panels.

WARNING ICONG 001CAUTION

Do not operate heater without glass panels installed. Operating heater without glass panels will damage front of heater due to excess temperatures.

WARNING ICONG 001CAUTION

Glass panels may have sharp edges. Handle with care.

2.Remove lower front access panel of heater by removing two screws at upper corners of panel. The lower front access panel covers the lower front access area (see Figure 9, page 14).

3.Remove two screws on glass guard. Remove glass guard (see Figure 11).

4.Carefully insert one glass panel up through lower front access area (see Figure 11).

5.Carefully slip glass panel behind hearth assembly (see Figure 11).

Glass

Guard

Screw

Hearth

Assembly

Glass

Panel

Lower Front

Access Area

Figure 11 - Inserting Glass Panels

Continued 15

100791

Image 15
Contents OWNER’S Operation and Installation Manual For Your SafetyWhat to do if YOU Smell GAS Contents Safety Information Safety Information Identification ProductUnpacking FeaturesInstalling Heater Local CodesInstalling Heater Venting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent Connecting to GAS Supply Qualified service person must connect heater to gasSupply. Follow all local codes Gas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemLocation of Radiants Installing RadiantsFor Radiant Models Only Installing Glass PanelInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Draft Hood Spillage Test AIR forVentilation Determining FRESH-AIR Flow for Heater LocationLeases poisonous carbon monoxide gas into your home 18 to make sure fresh air ventilation is adequate Confined area has an air volume of less than 50 cubicOperating Heater For Your Safety Read Before LightingViewing Pilot Shutting Off Heater Manual Lighting ProcedureBlower Operation To Turn OFF GAS to ApplianceInspecting Pilot and Burner Flame Pilot Flame PatternBurner Flame Pattern Flame Maintenance CleaningObserved Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Cleaning and MainteSee Changing Burner Orifice, Lighting Instructions Top Ing statement atRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Changing Burner Orifice WiringDiagram BlowerModel Technical ServiceService Hints 35,000 BTU/Hr 50,000 BTU/HrParts Ordering ReplacementParts Under Warranty Parts Not Under WarrantyBlower KIT Part Number GA6010 AccessoriesBlower Assembly Illustrated Parts ListIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100791 100791 Limited Warranty GVR/GVC Vented Propane GAS Heaters Warranty Information