Desa GVR65PA, GVR50PA Technical Service, Service Hints, 35,000 BTU/Hr 50,000 BTU/Hr, Model

Page 35

TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

35,000 BTU/Hr

50,000 BTU/Hr

65,000 BTU/Hr

 

Model

Model

Model

BTU

35,000

50,000

65,000

Type Gas

Propane Only

Propane Only

Propane Only

Ignition

Piezo

Piezo

Piezo

Pressure Regulator Setting 10.5" W.C.

10.5" W.C.

10.5" W.C.

Inlet Gas Pressure

 

 

 

Maximum

14" W.C.

14" W.C.

14" W.C.

Minimum

11" W.C.

11" W.C.

11" W.C.

Dimensions, Inches

 

 

 

Heater (H x W x D)

25 x 27 1/4 x 16

27 x 32 1/2 x 16

31 x 37 3/4 x 16

Shipping Weight (pounds) 97

133**/120

158**/145

Flue Vent Size

4" dia.

4" dia.

5" dia.

Orifice Size

52 drill, ø .0635

46 drill, ø .081

2.4 mm, ø .0945

** When equipped with blower

Note: These heaters are certified for elevations of 0-4500 feet above sea level. For elevations above 2000 feet, de-rate heater 4% for each 1000 feet above sea level.

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane gas supply may be low

When gas quality is bad

pilot will not stay lit

burner will produce yellow flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

100791

35

Image 35
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Safety Information Safety Information Identification ProductUnpacking FeaturesInstalling Heater Local CodesInstalling Heater Venting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent Supply. Follow all local codes Connecting to GAS SupplyQualified service person must connect heater to gas Gas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemLocation of Radiants Installing RadiantsFor Radiant Models Only Installing Glass PanelInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Draft Hood Spillage Test AIR forVentilation Determining FRESH-AIR Flow for Heater LocationLeases poisonous carbon monoxide gas into your home 18 to make sure fresh air ventilation is adequate Confined area has an air volume of less than 50 cubicOperating Heater For Your Safety Read Before LightingViewing Pilot Shutting Off Heater Manual Lighting ProcedureBlower Operation To Turn OFF GAS to ApplianceBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Flame Maintenance CleaningObserved Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Cleaning and MainteSee Changing Burner Orifice, Lighting Instructions Top Ing statement atRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Changing Burner Orifice WiringDiagram BlowerModel Technical ServiceService Hints 35,000 BTU/Hr 50,000 BTU/HrParts Ordering ReplacementParts Under Warranty Parts Not Under WarrantyBlower KIT Part Number GA6010 AccessoriesBlower Assembly Illustrated Parts ListIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100791 100791 Limited Warranty GVR/GVC Vented Propane GAS Heaters Warranty Information