Desa GVR50BPA, GVR65PA, GVR50PA, GVR65BPA, GVR35PA Blower, Wiring, Diagram, Changing Burner Orifice

Page 34

 

SERVICE

 

PROCEDURES

 

 

Continued

 

Changing Burner Orifice

Burner

1.

Shut off gas supply to

 

 

heater.

 

2.

Remove lower front

 

 

access panel on heater.

Orifice

3.

Disconnect burner tube

 

 

from orifice holder (see

Burner

 

Figure 25).

 

Tube

4.

Remove orifice holder

 

 

from burner (see Figure

 

 

25).

 

5.

Use socket or open-end

 

 

wrench to remove the old

Orifice

 

orifice from the orifice

 

Holder

 

holder.

 

6.

Clean and replace orifice,

Figure 25 - Orifice Location (35,000 BTU/Hr Burner Shown)

 

or replace with new

 

 

 

orifice.

 

7.Turn on gas to heater and check for gas leaks. Apply

a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

8.Replace lower front access panel.

Figure 26 - Orifice

BLOWER

 

 

Fan Switch

 

 

 

 

 

 

 

WIRING

 

 

(Off/On/Auto)

 

 

 

 

 

Auto

 

 

 

 

 

 

 

 

DIAGRAM

 

 

Off

 

 

 

 

 

 

 

 

(For Models With

 

 

On

 

Fan

 

 

 

 

 

Blower Assembly)

 

 

 

 

Red

 

 

 

 

Switch

 

 

 

 

 

 

 

 

Black Blue

 

(N.O.)

 

 

 

 

 

 

Black

 

 

 

 

 

 

Blower

 

110/115 V.A.C.

 

Motor

 

 

 

Black

 

Red

 

 

 

 

 

 

 

 

 

White

 

White

 

 

 

Green

 

 

 

 

 

 

 

 

 

34

100791

Image 34
Contents For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Safety Information Safety Information Product IdentificationLocal Codes FeaturesInstalling Heater UnpackingInstalling Heater Venting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Qualified service person must connect heater to gas Connecting to GAS SupplySupply. Follow all local codes Gas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Radiants Location of RadiantsInstalling Glass Panel For Radiant Models OnlyInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location AIR forVentilation Draft Hood Spillage TestLeases poisonous carbon monoxide gas into your home Confined area has an air volume of less than 50 cubic 18 to make sure fresh air ventilation is adequateFor Your Safety Read Before Lighting Operating HeaterViewing Pilot To Turn OFF GAS to Appliance Manual Lighting ProcedureBlower Operation Shutting Off HeaterPilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Flame Cleaning MaintenanceTrouble Shooting Observed Possible Problem Cause RemedyCleaning and Mainte TROUBLE- ShootingSee Changing Burner Orifice, Lighting Instructions Ing statement at TopService Procedures Removing Control Valve and Burner TubeRemoving Burner Blower WiringDiagram Changing Burner Orifice35,000 BTU/Hr 50,000 BTU/Hr Technical ServiceService Hints ModelParts Not Under Warranty Ordering ReplacementParts Under Warranty PartsAccessories Blower KIT Part Number GA6010Illustrated Parts List Blower AssemblyIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100791 100791 Warranty Information Limited Warranty GVR/GVC Vented Propane GAS Heaters