Desa GVR35PA, GVR65PA, GVR50PA, GVR65BPA, GVR50BPA Illustrated Parts List, Blower Assembly

Page 38

ILLUSTRATED

PARTS LIST

Blower

Assembly

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Ordering Replacement Parts on page 36 of this manual.

1

2

9

3

4

8

5 6

7

 

 

 

PART NUMBER FOR

 

 

 

KEY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO.

GVR65BPA

GVR65PA

 

GVR50BPA

GVR50PA

GVR35PA

DESCRIPTION

QTY.

 

 

 

 

 

 

 

 

 

1

099998-01

——

 

099998-01

——

——

Fan Switch

1

2

100045-01

——

 

100045-01

——

——

Wire Harness

1

3

231942

——

 

231942

——

——

Fan Limit Switch

1

4

M11084-38

——

 

M11084-38

——

——

Screw, #8-18 x 3/8"

2

5

100121-01

——

 

100121-01

——

——

Blower

1

6

M11084-26

——

 

M11084-26

——

——

Screw, #10-16 x 3/8"

6

7

531001

——

 

531001

——

——

Blower Pan

1

8

098304-01

——

 

098304-01

——

——

Screw, #10-24 x 3/8"

1

9

099123-01

——

 

099123-01

——

——

Thermobulb Clip

1

 

 

 

 

 

 

 

 

 

38

100791

Image 38
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Safety Information Safety Information Product IdentificationLocal Codes FeaturesInstalling Heater UnpackingInstalling Heater Venting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Supply. Follow all local codes Connecting to GAS SupplyQualified service person must connect heater to gas Gas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Radiants Location of RadiantsInstalling Glass Panel For Radiant Models OnlyInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location AIR forVentilation Draft Hood Spillage TestLeases poisonous carbon monoxide gas into your home Confined area has an air volume of less than 50 cubic 18 to make sure fresh air ventilation is adequateFor Your Safety Read Before Lighting Operating HeaterViewing Pilot To Turn OFF GAS to Appliance Manual Lighting ProcedureBlower Operation Shutting Off HeaterBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Flame Cleaning MaintenanceTrouble Shooting Observed Possible Problem Cause RemedyCleaning and Mainte TROUBLE- ShootingSee Changing Burner Orifice, Lighting Instructions Ing statement at TopService Procedures Removing Control Valve and Burner TubeRemoving Burner Blower WiringDiagram Changing Burner Orifice35,000 BTU/Hr 50,000 BTU/Hr Technical ServiceService Hints ModelParts Not Under Warranty Ordering ReplacementParts Under Warranty PartsAccessories Blower KIT Part Number GA6010Illustrated Parts List Blower AssemblyIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100791 100791 Warranty Information Limited Warranty GVR/GVC Vented Propane GAS Heaters