TROUBLE- | WARNING ICONG 001WARNING |
SHOOTING | If you smell gas |
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
OBSERVED | POSSIBLE | REMEDY |
|
|
| ||
PROBLEM | CAUSE |
|
|
| |||
|
|
|
|
| |||
Heater produces | 1. Heater burning vapors | 1. | Ventilate room. Stop | ||||
unwanted odors. |
| from paint, hair spray, |
| using odor causing | |||
|
| glues, etc. |
| products while heater is | |||
|
|
|
| running. | |||
| 2. | Low fuel supply | 2. | Refill supply tank. | |||
| 3. | Gas leak. See Warn- | 3. | Find and correct all | |||
|
| ing statement at |
| leaks (see Checking Gas | |||
|
| top of page. |
| Connections, page 13). | |||
|
|
|
|
|
|
| |
Heater shuts off in | 1. | Heater not venting | 1. | Check | venting system. | ||
use. |
| correctly. Vent safety |
| If damaged or blocked, | |||
|
| switch shuts off |
| repair. If venting system | |||
|
| heater. |
| is OK, | have qualified | ||
|
|
|
| service | person replace | ||
|
|
|
| vent safety switch, wire | |||
|
|
|
| harness, or thermo- | |||
|
|
|
| couple interrupter. | |||
| 2. | Low line pressure. | 2. | Contact local propane | |||
|
|
|
| gas company. | |||
| 3. | Pilot partially clogged. | 3. | Clean pilot (see Clean- | |||
|
|
|
| ing and Maintenance, | |||
|
|
|
| page 26). | |||
|
|
|
|
| |||
Gas odor even when | 1. Gas leak. See Warn- | 1. | Find and correct all | ||||
control knob is in |
| ing statement at |
| leaks (see Checking Gas | |||
OFF position. |
| top of page. |
| Connections, page 13). | |||
| 2. | Control valve damaged. | 2. | Replace control valve. | |||
|
|
|
|
| |||
Gas odor during | 1. Foreign matter be- | 1. | Take apart gas tubing | ||||
combustion. |
| tween control valve |
| and remove foreign | |||
|
| and burner. |
| matter. |
|
|
|
| 2. | Gas leak. See Warn- | 2. | Find and correct all | |||
|
| ing statement at |
| leaks (see Checking Gas | |||
|
| top of page. |
| Connections, page 13). | |||
| 3. | Foreign fumes in area | 3. | Ventilate area around | |||
|
| of heater being drawn |
| heater to remove any | |||
|
| through burner com- |
| foreign fumes. |
|
| |
|
|
| 31 | ||||
|
|
| |||||
|
| bustion. |
|
|
| ||
|
|
|
|
|
|
|
|
100791