MOUNTING AND WIRING THE SAFETY SENSORS

Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension. See Figure 5.

Finger tighten the wing nuts.

Run the wires from both sensors to the opener. Use insulated staples to secure wire to wall and ceiling.

Strip 1/4" of insulation from each set of wires. Separate white and white/black wires sufficiently to connect to the opener terminal screws: white to 2 and white/black to 3.

ALIGNING THE SAFETY SENSORS

Plug in the opener. The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct.

The sending eye orange indicator light will glow regardless of alignment or obstruction. If the green indicator light in the receiving eye is off, dim, or flickering (and the invisible light beam path is not obstructed), alignment is required.

Loosen the sending eye wing nut and readjust, aiming directly at the receiving eye. Lock in place.

Loosen the receiving eye wing nut and adjust sensor until it receives the sender’s beam. When the green indicator light glows steadily, tighten the wing nut.

Figure 5

Wing nut

1/4"-20x1/2"

Carriage bolt

Lens

TROUBLESHOOTING THE SAFETY SENSORS

1.If the sending eye indicator light does not glow steadily after installation, check for:

Electric power to the opener.

A short in the white or white/black wires. These can occur at staples, or at screw terminal connections.

Incorrect wiring between sensors and opener.

A broken wire.

2.If the sending eye indicator light glows steadily but the receiving eye indicator light doesn't:

Check alignment.

Check for an open wire to the receiving eye.

3.If the receiving eye indicator light is dim, realign either sensor.

NOTE: When the invisible beam path is obstructed or misaligned while the door is closing, the door will reverse. If the door is already open, it will not close. The door control will blink 10 times. See page 21.

Figure 6 Wiring the Safety Sensors

Connect Wire to

Opener Terminals

Bell Wire

 

Finished

 

Ceiling

 

 

 

Door Control

Sensor

Bell Wire

Connections

Connections

(dotted line)

 

 

 

12

3

OPENER TERMINAL SCREWS

Sensor

 

Invisible Light Beam

Sensor

Protection Area

23

Image 23
Contents Garage Door Opener Model 8200 Series Installation section pages 11 Start by reviewing these important safety alert symbolsContents Assembly section pages 8Youll Need Tools Closed Position Sectional Door InstallationOne-Piece Door With Track ONE-PIECE Door InstallationOne-Piece Door without Track Security Carton InventoryAssembly Right Wrong Assembly Section Pages 8Assembly Step Attach the Belt Pulley BracketFaster the T-rail to the Opener Install the Trolley on the T-railDo not use any tools Install the Belt & Set the Belt TensionCheck to make sure the belt is not twisted To attach the belt cap retainer Attach the Belt Cap RetainerProceed to , Installation Section Pages 12 Installation StepDetermine Header Bracket Location Sectional Door ONE-PIECE Door With Track=12 ExampleOne-piece door without track Jamb hardware One-piece door without track Pivot hardwareFasten the Header Bracket to the Ceiling Install the Header BracketFasten the Header Bracket to the Wall Attach the T-rail to the Header Bracket Raise the opener onto a stepladder Position the OpenerSectional Door & ONE-PIECE Door with Track Trolley slides with rail grease Hang the OpenerGrease the top Underside of the rail Surface whereTo opener terminal screws white to 2 white/red to Install the Multi-Function Door Control PanelOutside Keylock Accessory Connections Reverse the procedure to remove the lenses Install the Lights and the Lenses32 explains how to use the door control See Safety Reversing Sensor Instructions beginning onElectrical Requirements Permanent Wiring ConnectionFacing the door from inside the garage Protector SystemInstall the Safety Reversing Sensor Mounting and Wiring the Safety Sensors Fasten Door Bracket Sectional Door Installation ProcedureHeader Wall Hole Alignment Alternative Connect Door Arm to TrolleySectional Doors Only All ONE-PIECE Doors Adjustment Procedures for One-Piece DoorsHow and When to Adjust the Limits Adjustment Section Pages 28 Adjustment StepAdjust the UP and Down Limits Test the UP open force Adjust the ForceHow and When to Adjust the Forces Test the Down close forceTest the Protector System Test the Safety Reverse SystemImportant safety check Care of Your Opener Maintenance ScheduleLimit and Force Adjustment Controls Remote control batteryManual disconnect Position To open the door manually Operation of Your OpenerOperation of the Multi-Function Door Control Outside Keylock or Keyless EntryReceiver and Remote Control Programming Are the wiring connections correct? Review , Having a Problem?Situation Probable Cause & Solution Door control, a short under the staples, or a broken wireBulb if regular bulb burns out Is the Light feature on? Turn it offInstallation Parts Repair PartsRail Assembly Parts Complete with Opener Assembly PartsAccessories Available for your Opener Index Chamberlain Service Is on Call

8200 1/2 HP specifications

The Chamberlain 8200 is a robust and efficient garage door opener that combines power, reliability, and advanced technology to provide homeowners with a seamless experience. With its 1/2 HP motor, this opener is designed to handle sectional doors weighing up to 500 pounds, making it suitable for a variety of garage doors.

One of the standout features of the Chamberlain 8200 is its strong motor, which ensures smooth and quiet operation. This is particularly important for homeowners who have living spaces adjacent to the garage, as the reduced noise levels contribute to a more comfortable environment. The motor is also designed for durability and long-lasting performance, ensuring that it will consistently meet the needs of the user over time.

The Chamberlain 8200 comes equipped with the innovative MyQ technology, which enables users to control their garage door opener remotely via a smartphone app. This feature not only provides convenience but also enhances security, allowing homeowners to monitor and manage their garage door from anywhere. Whether you’re on vacation or simply at work, the ability to check the status of your garage door gives peace of mind.

Safety is another priority with the Chamberlain 8200, which includes features such as the patented Security+ 2.0 technology. This system ensures that your garage door opener transmits a new code every time the remote control is used, significantly reducing the risk of unauthorized access. Additionally, the opener is equipped with safety sensors that detect any obstructions in the door's path, preventing accidents or injuries.

Installation of the Chamberlain 8200 is straightforward, thanks to its detailed instructions and user-friendly design. The unit is compatible with a variety of garage door types and can easily integrate with existing door systems.

Overall, the Chamberlain 8200 1/2 HP garage door opener stands out as a powerful, technologically advanced solution for homeowners seeking convenience and security. Its blend of performance, innovative features, and user-friendly design makes it a top choice for modern garage door automation. Whether you are looking to upgrade your current system or installing a new opener, the Chamberlain 8200 promises reliability and peace of mind.