Programming Guide
Level I Programming
Parameters
P1 Time of day
P2 Time of regeneration
P3 Water hardness (grains per
P4 Salt usage per regeneration (lbs)
P5 System capacity (Kg)
Table 3: Level I programming parameters overview.
Default settings for models:
Setting | Description | 40DB | 48DB |
|
|
|
|
P1 | Time of day | Set to current time of day | |
|
|
|
|
P2 | Time of regeneration | 2 a.m. | 2 a.m. |
|
|
|
|
P3 | Water hardness | Set in field | Set in field |
|
|
|
|
P4* | Salt usage | 3.0 lbs | 3.6 lbs |
|
|
|
|
P5 | System capacity | 14.1 Kg | 15.2 Kg |
|
|
|
|
Table 4: Level I programming default settings.
* Default settings are representative of
Level I Settings are identified as those that have an LED indicator on the front panel. The green indicator illuminates next to the name of the active control setting. (See Figure 19.)
Pressing the down arrow [$] button displays the Level I settings in order. By continuing to press the down arrow [$] button, the settings start over beginning with the time of day. Pressing the up arrow [#] button displays the settings in reverse order.
Figure 19: Control valve interface.
Level I Programming
Parameters
P1 Time of Day AM or PM
Ranges: 1:00 to 12:59 or 00:00 to 23:59
Minimum Increments: 1 Min.
Units of Measure: Hours & Minutes
Range: Depends on the value selected for P13
P2 Time of Regeneration
Ranges: 1:00 to 12:59 a.m. or p.m, 00:00 to 23:59
Minimum Increments: 1 Min.
Units of Measure: Hours & Minutes
Range: Depends on the value selected for P13
P3 Water Hardness Setting
Range: 3 to 250 (grains per gallon) gpg / 30 to 2500 (milligrams per liter) Mg/L
Minimum Increments: 1 for (gpg), 10 for (Mg/L)
Units of Measure: Grains per gallon (gpg) / Milligram per liter (Mg/L)
Range: Unit of measure depends on the value selected for P12. Test water hardness (compensated hardness) and enter that value.
P4 Salt Amount (maximum)
Ranges: 0.5 to 99.5 (pounds) or 0.1 to 25.5 (kilograms)
Minimum Increments: 0.5 (pounds) or 0.1 (kilograms)
Units of Measure: Pounds or Kilograms
Range: Unit of measure and default depends on value selected for P12.
P5 System Capacity
Ranges: 0.1 to 140 Kgr or 0.01 to 14.0 Kgr
Minimum Increments: 0.1 Kgr or 0.01 Kgr
Units of Measure: Kgr or Kilograms
Range: Depends on value selected for P12