Specification guidelines.

www.GEAppliances.com

Product – height 15width 14depth 5.5

The system makes a good supply of drinking water each day.

How much it will make depends primarily on these things…

Feed water pressure limits—pounds per square inch (psi) . . . . . . . . . . . . . . . . . . . . . .40–125c

Feed water temperature limits—minimum/maximum degrees F . . . . . . . . . . . . . . . . .40–100

Maximum Total Dissolved Solids (TDS)—parts per million (ppm) . . . . . . . . . . . . . . . .2000

Maximum water hardness @ 6.9 pH recommended to optimize membrane life—grains per gallon (gpg) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Safety Instructions Operating

For water with hardness greater than 10 grains (at 6.9 pH) the use of a softener is recommended. Failure to install a water softener will reduce the life of the Reverse Osmosis membrane. See chart for additional information on the possible need for a water softener.

Hp

nI oc nim Wg ta re

8

7.5

7

6.5

6

WATER SOFTENER RECOMMENDED

Water Softener

not required

10

20

30

40

50

60

INCOMING WATER HARDNESS (GPG)

Instructions

Maximum iron, manganese, hydrogen sulfide (ppm) . . . . . . . . . . . . . . . . . . . . . .<0.1

Chlorine in water supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0 ppm maximum allowableb Feed water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–10

Product (quality) water, 24 hours—gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.0aPercent rejection of TDS (new membrane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92.4%a Cyst reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99.99% Storage tank capacity—gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4dEfficiency rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.7%e Recovery rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16.6%f Automatic shutoff control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .yes

Prefilter and postfilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FX12P) Carbon Block Reverse Osmosis membrane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FX12M) Thin Film Polyamide Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height 15” width 14” depth 5.5”

a.Tested according to NSF/ANSI Standard 58. Source water test parameters are 50 psig, 77°F, pH of 7.5 ± 0.5, and 750 ± 40 ppm total dissolved solids.

b.Removed by the Reverse Osmosis prefilter. REGULAR MAINTENANCE IS REQUIRED. Chlorine will destroy the Reverse Osmosis membrane.

c.If house water pressure is over 125 psi, install a pressure reducing valve in the water supply line. If house water pressure is under 40 psi, install a Reverse Osmosis booster pump (contact your local plumbing supply company).

d.Theoretical tank capacity. When tested according to NSF/ANSI Standard 58 at 50 psig inlet pressure, tank capacity is 2.3 gallons.

e.Efficiency rating means the percentage of the influent water to the system that is available to the user as Reverse Osmosis treated water under operating conditions that approximate typical daily usage.

f.Recovery rating means the percentage of influent water to the membrane portion of the system that is available to the user as Reverse Osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.

3

Installation Instructions Troubleshooting Tips Consumer Support

Image 3
Contents Osmosis Instructions Operating Instructions Safety PrecautionsMaximum iron, manganese, hydrogen sulfide ppm Specification guidelinesBefore YOU Begin Contents Included With ProductRO Faucet Basement InstallationFeed Water Drain PointPreferred Installation Optional Home InstallationFeed Water Supply Requires additional part Installation in a Remote LocationFaucet Installation Faucet Drain Tubing and Water Supply Tubing Filtration Drain Connection InstallationOption a Basement Access Installation Option B Drain Line Adapter InstallationNOW That Your Reverse Osmosis System is INSTALLED…SANITIZE Installation Instructions ″ Black tubing Compression Flownut control Screen Thin Film Polyamide Carbon BlockAbout the reverse osmosis system Consumer Support Troubleshooting TipsSafety Before you call for service… Parts list REF. no Part Description GXRM10GBL General Electric parts catalogTroubleshooting Tips Consumer Support Safety InstructionsGE Reverse Osmosis System Warranty Instructions Safety InstructionsOne Year Mesures de sécurité Fonctionnement Installation La section FrançaiseNuméro de modèle Numéro de série Clientèle Conseils de dépannage Fonctionnement InstallationMesures de sécurité Guide des spécificationsOutillage ET Matériel Requis Pour L’INSTALLATION Avant DE CommencerListe DES Composants DE L’APPAREIL Robinet RO Installation Dans UN SOUS-SOLEAU D’ALIMENTATION Point DE VidangeAlimentation D’EAU Installation PréférentielleSuite Installation À DistanceInstallation DU Robinet Raccordements À LA Conduite DE Vidange Option a Installation DU Système AU SOUS-SOLMise EN Garde Si le système Mise EN Garde Ne pas fermer De fuites Bloc de charbon Trousse de test d’eauSécurité Installation Conseils de dépannageService à la clientèle Au sujet du système de filtration par osmose inverséeDe sécurité Avant d’appeler un réparateur Service à la clientèle Conseils deListe de pièces Catalogue des pièces de Général Electric Manuel D’UTILISATION ET D’INSTALLATIONUn an Garantie du système de filtration par osmose inversée de GEService de réparations Soutien au consommateurProlongation de garantie La section en Español Seguridad Operación InstalaciónNúmero de modelo Número de serie Operación Instalación Servicio al consumidor Solucionar problemasSeguridad Pautas sobre las especificacionesContenidos Incluidos CON EL Producto Antes DE IniciarInstalación EN Sótano Agua DE AlimentaciónPunto DE Drenaje Grifo DEL Sistema DE OISuministro DE Agua DE Alimentación Instalación PreferidaInstalación Casera Opcional Instalación EN UNA Ubicación Remota Instalación CaseraInstalación DEL Grifo Instalación DE LA Conexión DEL Drenaje DE Filtración Opción a Instalación DE Acceso AL SótanoOpción B Instalación DEL Adaptador DEL Tubo DE Drenaje Del tanque Tubo DE Drenaje DEL Grifo Y Tubo DE Suministro DE AguaInstrucciones de instalación EN Exceso Poliamida de película delgada Cuidado y limpieza del sistema de Ósmosis InversaSobre el sistema de Ósmosis Inversa Instalación Servicio al consumidor Solucionar problemasControl del flujo Otro sabor y/u olor Sonidos que puedaEscuchar De aire y está turbiaAccesorios opcionales Lista de partesNO. REF Parte no Descripción DE LA Parte GXRM10GBL Catálogo de partes de General ElectricNotas Notas Notas Un año Seguridad OperaciónPiezas y accesorios Soporte al consumidor Página Web de GE AppliancesSolicite una reparación Garantías ampliadasConsumer Support GE Appliances Website Schedule Service