FEED WATER SUPPLY

Check and comply with local plumbing codes as you plan, then install a cold feed water supply fitting.

A. PREFERRED INSTALLATION

1.Close the cold water supply valve under the sink.

2.Unscrew the flexible tubing from the supply valve that connects to the COLD water riser.

3.Install the feed water adapter* that is the diameter to match either the 1/2or 3/8plumbing in your location. DO NOT

OVERTIGHTEN.

*Notice the direction of the feed water adapter and coupling. It is installed

differently in order to match either the 1/2or 3/8plumbing in your location.

 

 

 

For 3/8Plumbing

For 1/2Plumbing

 

 

 

B. OPTIONAL HOME INSTALLATION

Where codes permit (Requires additional parts)

*For 1/2OD or larger metal tubing only.

NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of the saddle valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts.

Saddle valve is available through GE Parts and Services at 1.800.626.2002, part number WS15X10023. Self piercing saddle valves are not recommended.

1.Turn off the cold water supply and attach saddle valve as shown in illustration below.

DANGER: Many homes are electrically grounded through the plumbing. To protect yourself from serious injury or fatal shock, use a battery-powered hand drill only to make the hole. DO NOT USE AN ELECTRIC DRILL.

Faucet tubing line

Ferrule

Coupling

Adapter Inlet valve

Nut Gasket

Inlet valve

Gasket

Faucet

tubing line

Coupling

Gasket

Adapter

2.Close the water supply valve by turning the handle clockwise.

3.Open the main water supply valve and several house faucets to purge air from the system. Close faucets when water runs smoothly.

Snug valve into bracket

(DO NOT OVERTIGHTEN)

Some threads should be visible

Rubber gasket

Optional water supply connection (using saddle valve)*

Cold water

supply valve

Cold water supply valve

*For 1/2 OD or larger metal tubing only.

Nut (2)—not

Pre-drill

1/4hole Seal—make sure

required if holes

the seal is in place

in clamp are

 

threaded

Clamp X

 

Clamp Z

Valve

 

Washer

 

Tubing adapter

Handle

Compression

Use to connect the tubing

nut

 

6

Image 6
Contents Osmosis Safety Precautions Instructions Operating InstructionsSpecification guidelines Maximum iron, manganese, hydrogen sulfide ppmContents Included With Product Before YOU BeginDrain Point Basement InstallationFeed Water RO FaucetPreferred Installation Optional Home InstallationFeed Water Supply Installation in a Remote Location Requires additional partFaucet Installation Option B Drain Line Adapter Installation Filtration Drain Connection InstallationOption a Basement Access Installation Faucet Drain Tubing and Water Supply TubingNOW That Your Reverse Osmosis System is INSTALLED…SANITIZE Installation Instructions ″ Black tubing Compression Flownut control Screen Carbon Block Thin Film PolyamideConsumer Support Troubleshooting Tips About the reverse osmosis systemSafety Before you call for service… Parts list General Electric parts catalog REF. no Part Description GXRM10GBLSafety Instructions Troubleshooting Tips Consumer SupportGE Reverse Osmosis System Warranty Instructions Safety InstructionsOne Year Mesures de sécurité Fonctionnement Installation La section FrançaiseNuméro de modèle Numéro de série Fonctionnement Installation Clientèle Conseils de dépannageGuide des spécifications Mesures de sécuritéOutillage ET Matériel Requis Pour L’INSTALLATION Avant DE CommencerListe DES Composants DE L’APPAREIL Point DE Vidange Installation Dans UN SOUS-SOLEAU D’ALIMENTATION Robinet ROInstallation Préférentielle Alimentation D’EAUInstallation À Distance SuiteInstallation DU Robinet Option a Installation DU Système AU SOUS-SOL Raccordements À LA Conduite DE VidangeMise EN Garde Si le système Mise EN Garde Ne pas fermer De fuites Trousse de test d’eau Bloc de charbonAu sujet du système de filtration par osmose inversée Installation Conseils de dépannageService à la clientèle SécuritéDe sécurité Service à la clientèle Conseils de Avant d’appeler un réparateurListe de pièces Manuel D’UTILISATION ET D’INSTALLATION Catalogue des pièces de Général ElectricGarantie du système de filtration par osmose inversée de GE Un anService de réparations Soutien au consommateurProlongation de garantie La section en Español Seguridad Operación InstalaciónNúmero de modelo Número de serie Servicio al consumidor Solucionar problemas Operación InstalaciónPautas sobre las especificaciones SeguridadAntes DE Iniciar Contenidos Incluidos CON EL ProductoGrifo DEL Sistema DE OI Agua DE AlimentaciónPunto DE Drenaje Instalación EN SótanoSuministro DE Agua DE Alimentación Instalación PreferidaInstalación Casera Opcional Instalación Casera Instalación EN UNA Ubicación RemotaInstalación DEL Grifo Instalación DE LA Conexión DEL Drenaje DE Filtración Opción a Instalación DE Acceso AL SótanoOpción B Instalación DEL Adaptador DEL Tubo DE Drenaje Tubo DE Drenaje DEL Grifo Y Tubo DE Suministro DE Agua Del tanqueInstrucciones de instalación EN Exceso Cuidado y limpieza del sistema de Ósmosis Inversa Poliamida de película delgadaInstalación Servicio al consumidor Solucionar problemas Sobre el sistema de Ósmosis InversaControl del flujo De aire y está turbia Sonidos que puedaEscuchar Otro sabor y/u olorLista de partes Accesorios opcionalesCatálogo de partes de General Electric NO. REF Parte no Descripción DE LA Parte GXRM10GBLNotas Notas Notas Seguridad Operación Un añoGarantías ampliadas Soporte al consumidor Página Web de GE AppliancesSolicite una reparación Piezas y accesoriosGE Appliances Website Schedule Service Consumer Support