Installation Instructions

FAUCET INSTALLATION

Be sure there is room underneath the sink to make the needed connections. Select one of the following locations to install the faucet:

In an existing sink spray attachment or soap dispenser hole.

In a hole to be drilled in the sink top.

In a hole to be drilled in the countertop, next to the sink.

NOTE: Be sure the faucet base will fit flat against the surface at the selected location so the gasket will seal.

1.If drilling is needed, make a 1-1/4dia. hole. Be sure to use the proper procedure for drilling porcelain or stainless steel.

2.Insert the faucet spout into the body. Tighten cap until snug.

3.Feed the blue, 1/4black and 3/8black tubes up through the hole in the countertop or sink.

4.Feed the two black tubes up through the gasket, faucet base and O-ring.

Spout

ASSEMBLED

Cap

Handle

Body

 

O-ring

 

Base

Mounting

Gasket

 

disk

 

5.Push the 1/4black and 3/8black tubing onto their respective barb fittings on the body.

6.Seat the base and body together. Make sure the O-ring and gasket are in place when the base meets the body. The faucet handle will be at the 3 o’clock position with respect to the base.

7.Slide the lock washer onto the threaded stem of the body, then thread the brass nut onto the stem. Screw about halfway up.

8.Screw the tubing adapter to the threaded stem of the body.

9.Push the blue tubing into the adapter. It should go in about 1/2. Pull on it to make sure it is installed securely.

10.Feed the tubing and stem back down through the 1-1/4hole.

11.Under the counter, insert the mounting disk above the lock washer and tighten the brass nut until snug.

3/8barb

 

fitting

 

1/4 barb

 

fitting

 

Lock washer

Black 3/8

Nut

tubing,

 

27long

Tubing adapter

 

Black 1/4

 

tubing

Blue 3/8tubing

 

Nut

Lock washer

Tubing adapter

NOTE: For ease of service and maintenance, keep tubing lengths long enough so removal of the Reverse Osmosis system from under the sink is possible.

8

From RO

To drain From RO

Image 8
Contents Osmosis Safety Precautions Instructions Operating InstructionsSpecification guidelines Maximum iron, manganese, hydrogen sulfide ppmContents Included With Product Before YOU BeginBasement Installation Feed WaterDrain Point RO FaucetFeed Water Supply Preferred InstallationOptional Home Installation Installation in a Remote Location Requires additional partFaucet Installation Filtration Drain Connection Installation Option a Basement Access InstallationOption B Drain Line Adapter Installation Faucet Drain Tubing and Water Supply TubingNOW That Your Reverse Osmosis System is INSTALLED…SANITIZE Installation Instructions ″ Black tubing Compression Flownut control Screen Carbon Block Thin Film PolyamideConsumer Support Troubleshooting Tips About the reverse osmosis systemSafety Before you call for service… Parts list General Electric parts catalog REF. no Part Description GXRM10GBLSafety Instructions Troubleshooting Tips Consumer SupportOne Year GE Reverse Osmosis System WarrantyInstructions Safety Instructions Numéro de modèle Numéro de série Mesures de sécurité Fonctionnement InstallationLa section Française Fonctionnement Installation Clientèle Conseils de dépannageGuide des spécifications Mesures de sécuritéListe DES Composants DE L’APPAREIL Outillage ET Matériel Requis Pour L’INSTALLATIONAvant DE Commencer Installation Dans UN SOUS-SOL EAU D’ALIMENTATIONPoint DE Vidange Robinet ROInstallation Préférentielle Alimentation D’EAUInstallation À Distance SuiteInstallation DU Robinet Option a Installation DU Système AU SOUS-SOL Raccordements À LA Conduite DE VidangeMise EN Garde Si le système Mise EN Garde Ne pas fermer De fuites Trousse de test d’eau Bloc de charbonInstallation Conseils de dépannage Service à la clientèleAu sujet du système de filtration par osmose inversée SécuritéDe sécurité Service à la clientèle Conseils de Avant d’appeler un réparateurListe de pièces Manuel D’UTILISATION ET D’INSTALLATION Catalogue des pièces de Général ElectricGarantie du système de filtration par osmose inversée de GE Un anProlongation de garantie Service de réparationsSoutien au consommateur Número de modelo Número de serie La section en EspañolSeguridad Operación Instalación Servicio al consumidor Solucionar problemas Operación InstalaciónPautas sobre las especificaciones SeguridadAntes DE Iniciar Contenidos Incluidos CON EL ProductoAgua DE Alimentación Punto DE DrenajeGrifo DEL Sistema DE OI Instalación EN SótanoInstalación Casera Opcional Suministro DE Agua DE AlimentaciónInstalación Preferida Instalación Casera Instalación EN UNA Ubicación RemotaInstalación DEL Grifo Opción B Instalación DEL Adaptador DEL Tubo DE Drenaje Instalación DE LA Conexión DEL Drenaje DE FiltraciónOpción a Instalación DE Acceso AL Sótano Tubo DE Drenaje DEL Grifo Y Tubo DE Suministro DE Agua Del tanqueInstrucciones de instalación EN Exceso Cuidado y limpieza del sistema de Ósmosis Inversa Poliamida de película delgadaInstalación Servicio al consumidor Solucionar problemas Sobre el sistema de Ósmosis InversaControl del flujo Sonidos que pueda EscucharDe aire y está turbia Otro sabor y/u olorLista de partes Accesorios opcionalesCatálogo de partes de General Electric NO. REF Parte no Descripción DE LA Parte GXRM10GBLNotas Notas Notas Seguridad Operación Un añoSoporte al consumidor Página Web de GE Appliances Solicite una reparaciónGarantías ampliadas Piezas y accesoriosGE Appliances Website Schedule Service Consumer Support