Installation Instructions
FILTRATION DRAIN CONNECTION INSTALLATION
Check and comply with all state and local plumbing codes as you plan.
CAUTION: The options detailed in this section are the ONLY approved installation configurations. Do not use any drain saddle device.
OPTION A: BASEMENT ACCESS INSTALLATION
Route the drain line (1/4″ black line) DIRECTLY from the Reverse Osmosis system to a standpipe in the basement,
Drain line from Reverse Osmosis
1/4″ Black tubing
Maintain air gap at drain point in basement
OPTION B: DRAIN LINE ADAPTER INSTALLATION
CAUTION!
DO NOT INSTALL DRAIN LINE ADAPTER DOWNSTREAM FROM DISPOSER.
Install the provided drain line adapter under the sink as shown. The
The tubing must be cut to length to provide
a straight routing from the faucet to the drain.
Drain line adapter in different line from disposer
Disposer
HOT COLD
Drain line is straight
Drain noise in the sink drain is normal when the Reverse Osmosis system is operating.
FAUCET DRAIN TUBING AND WATER SUPPLY TUBING
If OPTION A: BASEMENT ACCESS INSTALLATION (see Filtration Drain Connection Installation section, above) was used, go to Step 2.
1
If OPTION B: DRAIN LINE ADAPTER INSTALLATION was used, connect the faucet drain tubing by running the 3/8″ black tubing from the 3/8″ faucet barb to the drain fitting (installed in Filtration Drain Connection Installation section, above). Keep this tubing run as short and straight as possible, without loops, dips or low spots. Cut the tubing as needed and insert into the drain fitting.
2To connect the water supply tubing:
Run the 1/4″ yellow tubing from the Reverse Osmosis inlet to the feed water adapter (see illustrations in the Feed Water Supply section). Connect the tubing as applies (see Feed Water Supply section) and tighten the nut securely.
9