GE GXRM10G Filtration Drain Connection Installation, Faucet Drain Tubing and Water Supply Tubing

Page 9

Installation Instructions

FILTRATION DRAIN CONNECTION INSTALLATION

Check and comply with all state and local plumbing codes as you plan.

CAUTION: The options detailed in this section are the ONLY approved installation configurations. Do not use any drain saddle device.

OPTION A: BASEMENT ACCESS INSTALLATION

Route the drain line (1/4black line) DIRECTLY from the Reverse Osmosis system to a standpipe in the basement, by-passing the air gap provided in the faucet. The drain line may also be routed in the basement to a floor drain or washtub, provided that the air gap in the basement is maintained. Avoid dips, loops or low spots in the drain line. The basement air gap and drain installation configuration must conform to all local codes. Special air gap fittings are available from your local hardware store to connect the drain line to the top of the standpipe.

Drain line from Reverse Osmosis by-passing faucet air gap

1/4Black tubing

Maintain air gap at drain point in basement

OPTION B: DRAIN LINE ADAPTER INSTALLATION

CAUTION!

DO NOT INSTALL DRAIN LINE ADAPTER DOWNSTREAM FROM DISPOSER.

Install the provided drain line adapter under the sink as shown. The baffle-tee provided must be in place (purchase and install if necessary) to prevent a clog in the Reverse Osmosis drain line. Route the drain line (3/8black) from the faucet air gap to the drain line adapter, ensuring that there are no dips, loops or low spots in the line that could result in a clogged drain line.

The tubing must be cut to length to provide

a straight routing from the faucet to the drain.

Drain line adapter in different line from disposer

Disposer

HOT COLD

Drain line is straight

Drain noise in the sink drain is normal when the Reverse Osmosis system is operating.

FAUCET DRAIN TUBING AND WATER SUPPLY TUBING

If OPTION A: BASEMENT ACCESS INSTALLATION (see Filtration Drain Connection Installation section, above) was used, go to Step 2.

1

If OPTION B: DRAIN LINE ADAPTER INSTALLATION was used, connect the faucet drain tubing by running the 3/8black tubing from the 3/8faucet barb to the drain fitting (installed in Filtration Drain Connection Installation section, above). Keep this tubing run as short and straight as possible, without loops, dips or low spots. Cut the tubing as needed and insert into the drain fitting.

2To connect the water supply tubing:

Run the 1/4yellow tubing from the Reverse Osmosis inlet to the feed water adapter (see illustrations in the Feed Water Supply section). Connect the tubing as applies (see Feed Water Supply section) and tighten the nut securely.

9

Image 9
Contents Osmosis Instructions Operating Instructions Safety PrecautionsMaximum iron, manganese, hydrogen sulfide ppm Specification guidelinesBefore YOU Begin Contents Included With ProductFeed Water Basement InstallationDrain Point RO FaucetPreferred Installation Optional Home InstallationFeed Water Supply Requires additional part Installation in a Remote LocationFaucet Installation Option a Basement Access Installation Filtration Drain Connection InstallationOption B Drain Line Adapter Installation Faucet Drain Tubing and Water Supply TubingNOW That Your Reverse Osmosis System is INSTALLED…SANITIZE Installation Instructions ″ Black tubing Compression Flownut control Screen Thin Film Polyamide Carbon BlockAbout the reverse osmosis system Consumer Support Troubleshooting TipsSafety Before you call for service… Parts list REF. no Part Description GXRM10GBL General Electric parts catalogTroubleshooting Tips Consumer Support Safety InstructionsGE Reverse Osmosis System Warranty Instructions Safety InstructionsOne Year Mesures de sécurité Fonctionnement Installation La section FrançaiseNuméro de modèle Numéro de série Clientèle Conseils de dépannage Fonctionnement InstallationMesures de sécurité Guide des spécificationsOutillage ET Matériel Requis Pour L’INSTALLATION Avant DE CommencerListe DES Composants DE L’APPAREIL EAU D’ALIMENTATION Installation Dans UN SOUS-SOLPoint DE Vidange Robinet ROAlimentation D’EAU Installation PréférentielleSuite Installation À DistanceInstallation DU Robinet Raccordements À LA Conduite DE Vidange Option a Installation DU Système AU SOUS-SOLMise EN Garde Si le système Mise EN Garde Ne pas fermer De fuites Bloc de charbon Trousse de test d’eauService à la clientèle Installation Conseils de dépannageAu sujet du système de filtration par osmose inversée SécuritéDe sécurité Avant d’appeler un réparateur Service à la clientèle Conseils deListe de pièces Catalogue des pièces de Général Electric Manuel D’UTILISATION ET D’INSTALLATIONUn an Garantie du système de filtration par osmose inversée de GEService de réparations Soutien au consommateurProlongation de garantie La section en Español Seguridad Operación InstalaciónNúmero de modelo Número de serie Operación Instalación Servicio al consumidor Solucionar problemasSeguridad Pautas sobre las especificacionesContenidos Incluidos CON EL Producto Antes DE IniciarPunto DE Drenaje Agua DE AlimentaciónGrifo DEL Sistema DE OI Instalación EN SótanoSuministro DE Agua DE Alimentación Instalación PreferidaInstalación Casera Opcional Instalación EN UNA Ubicación Remota Instalación CaseraInstalación DEL Grifo Instalación DE LA Conexión DEL Drenaje DE Filtración Opción a Instalación DE Acceso AL SótanoOpción B Instalación DEL Adaptador DEL Tubo DE Drenaje Del tanque Tubo DE Drenaje DEL Grifo Y Tubo DE Suministro DE AguaInstrucciones de instalación EN Exceso Poliamida de película delgada Cuidado y limpieza del sistema de Ósmosis InversaSobre el sistema de Ósmosis Inversa Instalación Servicio al consumidor Solucionar problemasControl del flujo Escuchar Sonidos que puedaDe aire y está turbia Otro sabor y/u olorAccesorios opcionales Lista de partesNO. REF Parte no Descripción DE LA Parte GXRM10GBL Catálogo de partes de General ElectricNotas Notas Notas Un año Seguridad OperaciónSolicite una reparación Soporte al consumidor Página Web de GE AppliancesGarantías ampliadas Piezas y accesoriosConsumer Support GE Appliances Website Schedule Service