PROGRAMMING THE CONTROL

PROGRAMMING THE CONTROL

The green indicator lights up next to the name of the active control setting.

Pressing the DOWN button displays the settings in order. By continuing to press the DOWN button, the settings start over, beginning with the time of day. Pressing the UP button displays the settings in reverse order.

To change the settings, press the SET button on

the top right. A digit on the display will start to flash. If you want to change this number, press the UP button to increase the number or the DOWN button to decrease the number.

When the number is correct, press the LEFT button. The digit to the right will stop flashing and the next digit to the left starts flashing.

To skip the number without changing, press the LEFT button. When you reach the far left digit, press

the LEFT button to return to the digit on the right.

NOTE: If you press and hold either the UP or DOWN button for more than 1 second, the flashing number will increase or decrease at ten counts per second.

You can only change the flashing digit. Continue changing numbers until you reach the desired setting. Press the SET button. The numbers stop flashing and the control accepts the new settings. After approximately 30 seconds, the control starts alternating the display between TIME OF DAY and

CAPACITY.

NOTE: If the new setting is not accepted because it was outside the allowable range, the old value will be displayed. Refer to the table guides for correct settings.

SET PRESENT TIME OF DAY

PM Indicator light

Press UP or DOWN button to select TIME OF DAY.

1.Press the SET button. The display will show the time of day with the minutes blinking.

2.Press UP or DOWN button to set. The UP button advances the digit; the DOWN button moves the digit in reverse.

When the number is correct, press the LEFT button. The digit to the right will stop flashing and the next digit to the left starts flashing. You can only change the flashing number.

If the present time is between noon and midnight, be sure PM indicator light is on. If the present time is between midnight and noon, be sure PM indicator light is off.

To change AM/PM, advance the far left digit. The digit will alternate between 0 and 1. As the digit alternates, the PM light will turn on and off.

NOTE: Each press of an UP or DOWN button changes the digit by one minute. Holding the button changes the digit at a rapid rate.

3.When the present time is correct, press SET to accept.

11

Image 11
Contents Serial # Installation InstructionsWrite the model and serial numbers here Model # Safety Precautions Important Installation Recommendations Before Beginning InstallationUnpacking and Inspection Where to Install the SoftenerValve Bypass System Plan HOW YOU will Install SoftenerOptional 3-VALVE Bypass Installation Illustration Operation Install Bypass ValveBefore YOU Begin Drain Hose Connect and RUN the Valve Drain HoseBrine Tubing Connection Install Grounding Wire and ClampsRUN the Water Bypass Valve is Optional Open Water SupplyAdvance the Control Valve Purge the SystemWater Pressure Injector Part Number Connect to Electrical PowerInstall 9V Battery for Battery Backup Feature Injector SelectionSET Present Time of DAY Programming the ControlSalt PER Regen and Capacity Time of RegenerationTotal Water Hardness Example Capacity x 1,000 System Capacity InputsSounds YOU will Hear Error CodesNormal Operation Manual RegenerationSPECIFICATIONS/DIMENSIONS Sanitizing ProceduresAbout the water softener system Ge.com Cleaning the Injector and ScreenBreaking a Salt Bridge However, you must keep the tank supplied with salt Care and cleaning of the water softening systemCleaning Iron Out of the Water Softening System Checking the Salt Storage Level and RefillingTaken not plumbed to soft water Before you call for service…What To Do No soft waterWater feels slippery After installationNot using any salt After water softening System was installedColored water Brown/yellow colored Water after installationSalty tasting or Brown/yellowMinimum Units Parameter Description Range Increments Advanced programming and troubleshooting sectionAdvanced Programming Parameters Required Parameters Default SettingsManual Indexing for Each Regeneration Advanced troubleshootingErrors Error Detection CodesTroubleshooting Procedures Disc open. Replace if needed Run out of soft waterBetween regenerations Screen sectionWhat To Do Refill Position Flow diagramsService Position Brine Draw PositionFast Rinse Position Backwash PositionValve Disc Identification Water meter Checking the brine draw and refill functionControl valve diagram Systems diagram General Electric Parts Catalog Parts ListWarrantor General Electric Company. Louisville, KY What Is Not CoveredProduct not accessible to provide required service For The Period We Will ReplaceOne Year GE Water Softening System Warranty. For Customers in CanadaReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website