GE GNPR40L, GNPR48L installation instructions Troubleshooting Procedures

Page 25

ge.com

Troubleshooting Procedures

Problem

Possible Causes

What To Do

Capacity display stays at “9999” even though there is water usage

Total system capacity was calculated to be a value greater than 9999

As the water usage continues, the remaining capacity will drop below 9999, then other values will be shown.

Control does not respond

Button is not active in the

Wait for 30 seconds until lights begin to alternate.

to REGEN button

programming mode

 

Control does not display

Transformer is unplugged

Check connection to control and wall outlet.

time of day

No electric power at outlet

Repair outlet or use a working outlet.

 

Defective transformer

Replace transformer.

 

Defective circuit board

Replace control.

Control does not display

Outlet operated by a switch

Use an outlet not controlled by a switch.

correct time of day

Power outage

Reset time of day and replace battery.

No water flow display

Bypass valve in “bypass” position

Set bypass valve into “service” position.

when water is flowing

Meter probe disconnected or not fully

Fully insert probe into meter housing.

(colon doesn’t blink)

connected to meter housing

 

Restricted meter turbine rotation due to foreign material in meter

Remove bypass valve, free up turbine and flush with clean water. Turbine should spin freely. If not, refer to the Water Meter Maintenance section.

 

Defective meter probe

Replace control.

 

Defective circuit board

Replace control.

Control display is frozen Back to back regenerations were at REGEN TIME REMAINING requested

Refer to Manual Regeneration section.

Control regenerates at

Power outages

Reset time of day to correct time of day and replace battery.

 

 

the wrong time of day

 

Time of day set incorrectly

Reset time of day to correct time of day. Note PM light.

 

 

 

 

Time of regeneration set incorrectly

Reset time of regeneration. Note PM light.

 

 

Cam gear stalled in

Motor not operating

Replace motor assembly.

 

 

regeneration cycle

 

Motor runs backward

Replace motor assembly.

 

 

 

 

No electric power at outlet

Repair outlet or use a working outlet.

 

 

 

 

Broken gear

Replace gear.

 

 

 

 

Defective switch

Replace switch.

 

 

 

 

Binding of cam gear

Remove foreign object obstruction from valve discs or cam

 

 

 

 

 

gear.

 

 

 

 

Water pressure greater than 125 psi

Install pressure regulator to reduce pressure.

 

 

 

 

during regeneration

 

 

 

 

 

Defective circuit board

Replace control.

 

 

Continuous regeneration. Defective switch

Replace switch.

 

 

Cam gear does not stop

 

 

 

 

at the end of regeneration.

 

 

 

 

Control does not

Transformer unplugged

Connect power.

 

 

regenerate automatically

 

No electric power at outlet

Repair outlet or use a working outlet.

 

 

or when REGEN button is

 

 

 

 

 

 

Defective motor

Replace motor assembly.

 

 

pressed

 

 

 

 

 

 

Defective switch

Replace switch.

 

 

 

 

 

 

Control does not

If water flow display is not operative,

Refer to “No water flow display when water is flowing”

 

 

regenerate automatically refer to “No water flow display

in this table.

 

 

but does regenerate when when water is flowing” in this table

 

 

 

REGEN button is pressed

 

Incorrect hardness and capacity

Set new control values. See the Programming the Control

 

 

 

 

settings

section.

 

 

 

 

Defective circuit board

Replace control.

25

 

 

 

 

Image 25
Contents Write the model and serial numbers here Model # Installation InstructionsSerial # Safety Precautions Important Installation Recommendations Before Beginning InstallationUnpacking and Inspection Where to Install the SoftenerOptional 3-VALVE Bypass Installation Illustration Plan HOW YOU will Install SoftenerValve Bypass System Before YOU Begin Install Bypass ValveOperation Drain Hose Connect and RUN the Valve Drain HoseBrine Tubing Connection Install Grounding Wire and ClampsAdvance the Control Valve Bypass Valve is Optional Open Water SupplyPurge the System RUN the WaterInstall 9V Battery for Battery Backup Feature Connect to Electrical PowerInjector Selection Water Pressure Injector Part NumberSET Present Time of DAY Programming the ControlTotal Water Hardness Time of RegenerationSalt PER Regen and Capacity Example Capacity x 1,000 System Capacity InputsNormal Operation Error CodesManual Regeneration Sounds YOU will HearSPECIFICATIONS/DIMENSIONS Sanitizing ProceduresAbout the water softener system Breaking a Salt Bridge Cleaning the Injector and ScreenGe.com Cleaning Iron Out of the Water Softening System Care and cleaning of the water softening systemChecking the Salt Storage Level and Refilling However, you must keep the tank supplied with saltWhat To Do Before you call for service…No soft water Taken not plumbed to soft waterNot using any salt After installationAfter water softening System was installed Water feels slipperySalty tasting or Brown/yellow colored Water after installationBrown/yellow Colored waterAdvanced Programming Parameters Advanced programming and troubleshooting sectionMinimum Units Parameter Description Range Increments Required Parameters Default SettingsErrors Advanced troubleshootingError Detection Codes Manual Indexing for Each RegenerationTroubleshooting Procedures Between regenerations Run out of soft waterScreen section Disc open. Replace if neededWhat To Do Service Position Flow diagramsBrine Draw Position Refill PositionValve Disc Identification Backwash PositionFast Rinse Position Water meter Checking the brine draw and refill functionControl valve diagram Systems diagram General Electric Parts Catalog Parts ListProduct not accessible to provide required service What Is Not CoveredFor The Period We Will Replace Warrantor General Electric Company. Louisville, KYOne Year GE Water Softening System Warranty. For Customers in CanadaParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio