ge.com
Default Settings
The following table represents preset values programmed into the system at the factory for both levels for the model shown.
Required Parameters
Name | Description | GNPR40L | GNPR48L |
P1 | Time of day | Set in field | Set in field |
|
|
|
|
P2 | Time of regeneration | 2:00 a.m. | 2:00 a.m. |
|
|
|
|
P3 | Hardness | Set in field (25 grains) | Set in field (25 grains) |
|
|
|
|
P4 | Salt amount | 7.5 lbs | 9.0 lbs |
|
|
|
|
P5 | Capacity | 24.4 Kgr | 26.1 Kgr |
|
|
|
|
Advanced Programming Parameters
Name | Description | GNPR40L | GNPR48L |
P6 | Refill controller | 0.33 gpm | 0.33 gpm |
|
|
|
|
P7 | Brine draw value | 15 min. | 16 min. |
|
|
|
|
P8 | Not used | N/A | N/A |
|
|
|
|
P9 | Backwash time | 12 min. | 12 min. |
|
|
|
|
P10 | Slow rinse time | 67 min. | 83 min. |
|
|
|
|
P11 | Fast rinse time | 4.0 min. | 4.0 min. |
|
|
|
|
P12 | Units of measure | 0 | 0 |
|
|
|
|
P13 | Clock mode | 0 | 0 |
|
|
|
|
P14 | Calendar override | 0 | 0 |
|
|
|
|
P15 | Reserve type | 0 | 0 |
|
|
|
|
P16 | Fixed reserve capacity | N/A | N/A |
| or initial average value |
|
|
|
|
|
|
P17 | Operation type | 1 | 1 |
|
|
|
|
P18 | Salt/capacity change | 0 | 0 |
| lock out |
|
|
|
|
|
|
P19 | Factory defaults | 9 | 9 |
|
|
|
|
23