GE GNPR48L, GNPR40L Normal Operation, Manual Regeneration, Error Codes, Sounds YOU will Hear

Page 14

Installation Instructions

NORMAL OPERATION

The control will cycle between TIME OF DAY and CAPACITY about every 10 seconds, as indicated by the green indicator light.

Capacity in Normal Operation mode is the gallons of water available until the next regeneration cycle.

During a regeneration cycle, the control will cycle between TIME OF DAY and REGEN TIME REMAINING.

REGEN TIME REMAINING is the number of minutes until the regeneration cycle is complete.

MANUAL REGENERATION

Occasionally you may find it necessary to initiate a manual regeneration. This is done by pressing the REGEN button on the front of the display. When you press the REGEN button, the control performs a full regeneration of the water conditioner immediately.

In the event the system is allowed to run out

of salt, it will be necessary to run “Back to Back” regenerations. This can be done easily by pressing the REGEN button one time, waiting at least one minute and pressing the REGEN button again.

NOTE: The second regeneration will begin immediately after the first is completed.

“Back to Back” regenerations are necessary if full exhaustion occurs due to low regenerate levels or system malfunction. The system works on a highly efficient proportionate-brining method. When the system is not aware of the lack of proper regenerate (salt), a larger portion of the resin bed becomes exhausted.

REGEN button

ERROR CODES

This system continuously monitors itself and displays an error message if it detects something wrong. This typically happens when the valve has not advanced through the regeneration cycle properly.

When an error is detected, the display shows the letters “Err” with a number from 1 to 4. The table on page 24 describes each error, the cause of the error and the solutions.

To clear the error from the display, press any button on the control. If the error still exists, the control will display the error message again after 30 seconds.

SOUNDS YOU WILL HEAR

During the regeneration cycle, the softener makes several sounds. These sounds are normal.

Clicking sound – This occurs as the valve assembly advances. It is the opening and closing of the valve ports.

Harmonic sound – As the valve transitions between cycles in regeneration, a high-pitched harmonic noise may be heard for a few seconds.

Water flow sound – In the backwash and purge portions of the regeneration, water flow is very high – 2–3 gpm. This is required to flush the tank of accumulated minerals and sediments.

14

Image 14
Contents Serial # Installation InstructionsWrite the model and serial numbers here Model # Safety Precautions Before Beginning Installation Important Installation RecommendationsWhere to Install the Softener Unpacking and InspectionValve Bypass System Plan HOW YOU will Install SoftenerOptional 3-VALVE Bypass Installation Illustration Operation Install Bypass ValveBefore YOU Begin Connect and RUN the Valve Drain Hose Drain HoseInstall Grounding Wire and Clamps Brine Tubing ConnectionPurge the System Bypass Valve is Optional Open Water SupplyAdvance the Control Valve RUN the WaterInjector Selection Connect to Electrical PowerInstall 9V Battery for Battery Backup Feature Water Pressure Injector Part NumberProgramming the Control SET Present Time of DAYSalt PER Regen and Capacity Time of RegenerationTotal Water Hardness System Capacity Inputs Example Capacity x 1,000Manual Regeneration Error CodesNormal Operation Sounds YOU will HearSanitizing Procedures SPECIFICATIONS/DIMENSIONSAbout the water softener system Ge.com Cleaning the Injector and ScreenBreaking a Salt Bridge Checking the Salt Storage Level and Refilling Care and cleaning of the water softening systemCleaning Iron Out of the Water Softening System However, you must keep the tank supplied with saltNo soft water Before you call for service…What To Do Taken not plumbed to soft waterAfter water softening System was installed After installationNot using any salt Water feels slipperyBrown/yellow Brown/yellow colored Water after installationSalty tasting or Colored waterMinimum Units Parameter Description Range Increments Advanced programming and troubleshooting sectionAdvanced Programming Parameters Default Settings Required ParametersError Detection Codes Advanced troubleshootingErrors Manual Indexing for Each RegenerationTroubleshooting Procedures Screen section Run out of soft waterBetween regenerations Disc open. Replace if neededWhat To Do Brine Draw Position Flow diagramsService Position Refill PositionFast Rinse Position Backwash PositionValve Disc Identification Checking the brine draw and refill function Water meterControl valve diagram Systems diagram Parts List General Electric Parts CatalogFor The Period We Will Replace What Is Not CoveredProduct not accessible to provide required service Warrantor General Electric Company. Louisville, KYGE Water Softening System Warranty. For Customers in Canada One YearConsumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design Studio