GE GNPR40L, GNPR48L Backwash Position, Valve Disc Identification, Fast Rinse Position

Page 29

ge.com

5 Backwash Position

Inlet

 

Outlet

 

 

Drain

 

 

Treated Water

 

 

Untreated Water

 

Valve

 

No.

Description

Position

1

Brine

Closed

2

Upper Drain

Open

3

Inlet

Closed

4

Bypass

Open

5

Outlet

Open

6

Lower Drain

Closed

7

Center Dist.

Closed

Valve Disc Identification

Disc 6 – Lower Drain

6 Fast Rinse Position

Inlet

 

Outlet

 

 

Drain

 

 

Treated Water

 

 

Untreated Water

 

Valve

 

No.

Description

Position

1

Brine

Closed

2

Upper Drain

Closed

3

Inlet

Open

4

Bypass

Open

5

Outlet

Closed

6

Lower Drain

Open

7

Center Dist.

Closed

Disc 5 – Outlet

Disc 3 – Inlet

Disc 2 – Upper Drain

Disc 4 – Bypass

Disc 7 – Center Distributor

Disc 1 – Brine

 

29

Image 29
Contents Serial # Installation InstructionsWrite the model and serial numbers here Model # Safety Precautions Important Installation Recommendations Before Beginning InstallationUnpacking and Inspection Where to Install the SoftenerValve Bypass System Plan HOW YOU will Install SoftenerOptional 3-VALVE Bypass Installation Illustration Operation Install Bypass ValveBefore YOU Begin Drain Hose Connect and RUN the Valve Drain HoseBrine Tubing Connection Install Grounding Wire and ClampsAdvance the Control Valve Bypass Valve is Optional Open Water SupplyPurge the System RUN the WaterInstall 9V Battery for Battery Backup Feature Connect to Electrical PowerInjector Selection Water Pressure Injector Part NumberSET Present Time of DAY Programming the ControlSalt PER Regen and Capacity Time of RegenerationTotal Water Hardness Example Capacity x 1,000 System Capacity InputsNormal Operation Error CodesManual Regeneration Sounds YOU will HearSPECIFICATIONS/DIMENSIONS Sanitizing ProceduresAbout the water softener system Ge.com Cleaning the Injector and ScreenBreaking a Salt Bridge Cleaning Iron Out of the Water Softening System Care and cleaning of the water softening systemChecking the Salt Storage Level and Refilling However, you must keep the tank supplied with saltWhat To Do Before you call for service…No soft water Taken not plumbed to soft waterNot using any salt After installationAfter water softening System was installed Water feels slipperySalty tasting or Brown/yellow colored Water after installationBrown/yellow Colored waterMinimum Units Parameter Description Range Increments Advanced programming and troubleshooting sectionAdvanced Programming Parameters Required Parameters Default SettingsErrors Advanced troubleshootingError Detection Codes Manual Indexing for Each RegenerationTroubleshooting Procedures Between regenerations Run out of soft waterScreen section Disc open. Replace if neededWhat To Do Service Position Flow diagramsBrine Draw Position Refill PositionFast Rinse Position Backwash PositionValve Disc Identification Water meter Checking the brine draw and refill functionControl valve diagram Systems diagram General Electric Parts Catalog Parts ListProduct not accessible to provide required service What Is Not CoveredFor The Period We Will Replace Warrantor General Electric Company. Louisville, KYOne Year GE Water Softening System Warranty. For Customers in CanadaParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio