Advanced troubleshooting.

Problem

Possible Causes

What To Do

Run out of soft water

Incorrect injector

With water pressure > 70 psi, use 4 bump injectors

between regenerations

 

(WS15X10059).

 

Improper regeneration

Repeat regeneration, making certain correct salt dosage is

 

 

used.

 

Fouled resin bed

Use resin cleaner.

 

Incorrect salt dose and capacity setting • Set Salt per Regen and Capacity setting to proper level. Refer to

 

 

the Programming the Control sections.

 

Incorrect hardness

Set to correct hardness. Refer to the Programming the

 

 

Control sections.

 

Water hardness has increased

Set to new value. Refer to the Programming the Control

 

 

sections.

 

Restricted meter turbine rotation due • Remove bypass, free up turbine and flush with clean

 

to foreign material in meter housing

water. Turbine should spin freely—if not, replace meter.

 

Water usage below 1/5 gallon

Repair leaky plumbing and/or fixtures.

 

per minute

 

Brine draw value from Advanced Programming Parameters table is incorrect

Set correct brine draw value.

Incorrect salt type or use of grid plate (salt shelf)

Do not use block salt or grid plate (salt shelf) in brine tank.

Control does not draw

Low water pressure

Increase water pressure (20 psi at conditioner).

brine

Restricted drain line

Remove obstruction.

 

Injector or injector screen is plugged

Clean injector and screen. Refer to the Cleaning the Injector and

 

 

Screen section.

 

Injector defective

Replace injector and cap.

 

Valve disc 3 and/or 5 not closed

Manually operate cam gear to flush out foreign matter holding

 

 

disc open. Replace if needed.

 

Air check valve prematurely closed

Briefly put control into brine refill status. Refer to the Manual

 

 

Regeneration section. Repair air check valve if needed.

Brine tank overflow

Brine valve disc 1 held open

Manually operate cam gear to flush out foreign matter holding

 

 

disc open.

 

Valve disc 2 not closed during brine

Manually operate cam gear to flush out foreign matter holding

 

draw, causing brine refill

disc open.

 

Air leak in brine line to air check

Check all connections in brine line for leaks.

 

Salt setting too high

Set in new values. Refer to Advanced Programming section.

 

Float assembly malfunctions

Inspect float assembly in brine well for proper operation.

 

 

It must be able to move freely.

Intermittent or irregular

Low water pressure

Increase water pressure (20 psi at conditioner).

brine draw

Defective injector

Replace both injector and injector cap.

No conditioned water

Unit did not regenerate

Check for power.

after regeneration

No salt in brine tank

Add salt to brine tank.

 

Plugged injector

Remove injector and flush it and injector screen.

 

Air check valve closed prematurely

Put control momentarily into REFILL to free air check. Replace

 

 

or repair air check as needed.

Incorrect salt type or use of grid plate (salt shelf) in brine tank

Do not use block salt or grid plate (salt shelf) in brine tank.

Control backwashes at

Incorrect backwash controller

Replace with correct size controller.

excessively low or high

Foreign matter affecting controller

Remove and clean controller.

rate

operation

 

26

Image 26
Contents Serial # Installation InstructionsWrite the model and serial numbers here Model # Safety Precautions Before Beginning Installation Important Installation RecommendationsWhere to Install the Softener Unpacking and InspectionValve Bypass System Plan HOW YOU will Install SoftenerOptional 3-VALVE Bypass Installation Illustration Operation Install Bypass ValveBefore YOU Begin Connect and RUN the Valve Drain Hose Drain HoseInstall Grounding Wire and Clamps Brine Tubing ConnectionPurge the System Bypass Valve is Optional Open Water SupplyAdvance the Control Valve RUN the WaterInjector Selection Connect to Electrical PowerInstall 9V Battery for Battery Backup Feature Water Pressure Injector Part NumberProgramming the Control SET Present Time of DAYSalt PER Regen and Capacity Time of RegenerationTotal Water Hardness System Capacity Inputs Example Capacity x 1,000Manual Regeneration Error CodesNormal Operation Sounds YOU will HearSanitizing Procedures SPECIFICATIONS/DIMENSIONSAbout the water softener system Ge.com Cleaning the Injector and ScreenBreaking a Salt Bridge Checking the Salt Storage Level and Refilling Care and cleaning of the water softening systemCleaning Iron Out of the Water Softening System However, you must keep the tank supplied with saltNo soft water Before you call for service…What To Do Taken not plumbed to soft waterAfter water softening System was installed After installationNot using any salt Water feels slipperyBrown/yellow Brown/yellow colored Water after installationSalty tasting or Colored waterMinimum Units Parameter Description Range Increments Advanced programming and troubleshooting sectionAdvanced Programming Parameters Default Settings Required ParametersError Detection Codes Advanced troubleshootingErrors Manual Indexing for Each RegenerationTroubleshooting Procedures Screen section Run out of soft waterBetween regenerations Disc open. Replace if neededWhat To Do Brine Draw Position Flow diagramsService Position Refill PositionFast Rinse Position Backwash PositionValve Disc Identification Checking the brine draw and refill function Water meterControl valve diagram Systems diagram Parts List General Electric Parts CatalogFor The Period We Will Replace What Is Not CoveredProduct not accessible to provide required service Warrantor General Electric Company. Louisville, KYGE Water Softening System Warranty. For Customers in Canada One YearConsumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design Studio