GE GNPR48L, GNPR40L installation instructions Care and cleaning of the water softening system

Page 18

Care and cleaning of the water softening system.

Checking the Salt Storage Level and Refilling

Brine (salt dissolved in water) is needed for each and every regeneration. The water for making brine is metered into the salt storage area by the water softening system valve and control.

However, you must keep the tank supplied with salt.

Use clean water softening salts only, at least 99.5% pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. They contain dirt and sediments, or mush and cake, and will create maintenance problems.

CAUTION: Water softening salt with iron removing additives: Some salts may have an additive to help the water softening system handle iron in the water supply. Although this additive may help to keep the water softening system resin clean, it may also release corrosive fumes that weaken and shorten the life of some water softening system parts. GE recommends using only Diamond Crystal® Red•Out® brand salt.

Cleaning Iron Out of the Water Softening System

Your water softening system takes hardness minerals (calcium and magnesium) out of the water. Also, it can control some (see the Specification Guidelines section) “clear water” iron. With clear water iron, water from a faucet is clear when first put into a glass. After 15 to 30 minutes, the water begins to cloud or turn rust colored. A water softening system will not remove any iron that makes the water cloudy or rusty as it comes from the faucet (called red water iron). To take red water iron out of water, or over the maximum of clear water iron,

an iron filter or other equipment is needed.

GE recommends using only Diamond Crystal® Red•Out® brand salts with Iron Fighter® additive to help keep the resin bed clean of clear iron. If your water supply has clear water iron, periodic resin bed cleaning is needed. GE recommends using Super Iron Out® brand resin bed cleaner to thoroughly clean your resin bed if your iron content is high. Clean the bed at least every six months, or more often if iron appears in the soft water between cleanings.

IMPORTANT: It is important to mix the resin bed cleaner with water (following the manufacturer’s instructions), pour it into the brinewell tube (see page 5) and regenerate the softener immediately. Do not pour the resin bed cleaner in with the salt, as it will not be as effective in cleaning the resin, and can cause damage to the softener if it is left in the brine tank for an extended period due to the corrosive gases that are formed.

The control has an adjustable backwash cycle. The backwash can be lengthened to better flush the resin bed from high sediment

or iron situations. See the Advanced Control Setting section or consult an installer.

Also set LBS OF SALT and CAPACITY so the system will regenerate about every 3 days. See page 13.

18

Image 18
Contents Installation Instructions Write the model and serial numbers here Model #Serial # Safety Precautions Before Beginning Installation Important Installation RecommendationsWhere to Install the Softener Unpacking and InspectionPlan HOW YOU will Install Softener Optional 3-VALVE Bypass Installation IllustrationValve Bypass System Install Bypass Valve Before YOU BeginOperation Connect and RUN the Valve Drain Hose Drain HoseInstall Grounding Wire and Clamps Brine Tubing ConnectionPurge the System Bypass Valve is Optional Open Water SupplyAdvance the Control Valve RUN the WaterInjector Selection Connect to Electrical PowerInstall 9V Battery for Battery Backup Feature Water Pressure Injector Part NumberProgramming the Control SET Present Time of DAYTime of Regeneration Total Water HardnessSalt PER Regen and Capacity System Capacity Inputs Example Capacity x 1,000Manual Regeneration Error CodesNormal Operation Sounds YOU will HearSanitizing Procedures SPECIFICATIONS/DIMENSIONSAbout the water softener system Cleaning the Injector and Screen Breaking a Salt BridgeGe.com Checking the Salt Storage Level and Refilling Care and cleaning of the water softening systemCleaning Iron Out of the Water Softening System However, you must keep the tank supplied with saltNo soft water Before you call for service…What To Do Taken not plumbed to soft waterAfter water softening System was installed After installationNot using any salt Water feels slipperyBrown/yellow Brown/yellow colored Water after installationSalty tasting or Colored waterAdvanced programming and troubleshooting section Advanced Programming ParametersMinimum Units Parameter Description Range Increments Default Settings Required ParametersError Detection Codes Advanced troubleshootingErrors Manual Indexing for Each RegenerationTroubleshooting Procedures Screen section Run out of soft waterBetween regenerations Disc open. Replace if neededWhat To Do Brine Draw Position Flow diagramsService Position Refill PositionBackwash Position Valve Disc IdentificationFast Rinse Position Checking the brine draw and refill function Water meterControl valve diagram Systems diagram Parts List General Electric Parts CatalogFor The Period We Will Replace What Is Not CoveredProduct not accessible to provide required service Warrantor General Electric Company. Louisville, KYGE Water Softening System Warranty. For Customers in Canada One YearConsumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design Studio