GE GNPR40L Bypass Valve is Optional Open Water Supply, Advance the Control Valve, RUN the Water

Page 9

Installation Instructions

START-UP RINSING PROCEDURE

(BYPASS VALVE IS OPTIONAL)

1 OPEN WATER SUPPLY

With the plumbing, drain line and overflow connections completed, slowly open the water supply, allowing the lines to pressurize.

NOTE: The optional bypass should still be in bypass mode as shown.

OutletInlet

2 ADVANCE THE CONTROL VALVE

With the transformer unplugged, manually advance the control valve by depressing the drive gear and rotating the main system gear to the purge position (see Step 4).

3 PURGE THE SYSTEM

Slowly open the inlet valve (only) on the bypass valve to the half-opened position, allowing the system to pressurize. It is normal to hear air blowing to the drain during this procedure.

Once the air clears and water begins to run to

the drain, open the inlet valve (only) to the full open position and allow the water to run to the drain in purge for a minimum of 20 minutes.

4 RUN THE WATER

After the 20-minute purge cycle, manually advance the main gear to the backwash cycle and allow to run for a minimum of 10 minutes.

After 10 minutes during the backwash cycle, open both the inlet and outlet valves on the bypass to the fully opened position.

NOTE: When advancing the main gear manually while under water pressure, it is normal for the gear to encounter resistance as the valve chambers depressurize. If resistance occurs, pause five seconds to allow the valve to depressurize

before advancing to the next step.

Advance the gear in the counterclockwise direction only. Damage will occur if advanced in the opposite direction.

5 FILL BRINE TANK

After the ten-minute backwash cycle, manually advance the control valve to the brine refill position for ten minutes, allowing water to flow into the brine storage tank.

OutletInlet

9

Once water begins to flow into the tank, fill the brine tank with a minimum of 80 lbs. of salt pellets.

Image 9
Contents Installation Instructions Write the model and serial numbers here Model #Serial # Safety Precautions Important Installation Recommendations Before Beginning InstallationUnpacking and Inspection Where to Install the SoftenerPlan HOW YOU will Install Softener Optional 3-VALVE Bypass Installation IllustrationValve Bypass System Install Bypass Valve Before YOU BeginOperation Drain Hose Connect and RUN the Valve Drain HoseBrine Tubing Connection Install Grounding Wire and ClampsAdvance the Control Valve Bypass Valve is Optional Open Water SupplyPurge the System RUN the WaterInstall 9V Battery for Battery Backup Feature Connect to Electrical PowerInjector Selection Water Pressure Injector Part NumberSET Present Time of DAY Programming the ControlTime of Regeneration Total Water HardnessSalt PER Regen and Capacity Example Capacity x 1,000 System Capacity InputsNormal Operation Error CodesManual Regeneration Sounds YOU will HearSPECIFICATIONS/DIMENSIONS Sanitizing ProceduresAbout the water softener system Cleaning the Injector and Screen Breaking a Salt BridgeGe.com Cleaning Iron Out of the Water Softening System Care and cleaning of the water softening systemChecking the Salt Storage Level and Refilling However, you must keep the tank supplied with saltWhat To Do Before you call for service…No soft water Taken not plumbed to soft waterNot using any salt After installationAfter water softening System was installed Water feels slipperySalty tasting or Brown/yellow colored Water after installationBrown/yellow Colored waterAdvanced programming and troubleshooting section Advanced Programming ParametersMinimum Units Parameter Description Range Increments Required Parameters Default SettingsErrors Advanced troubleshootingError Detection Codes Manual Indexing for Each RegenerationTroubleshooting Procedures Between regenerations Run out of soft waterScreen section Disc open. Replace if neededWhat To Do Service Position Flow diagramsBrine Draw Position Refill PositionBackwash Position Valve Disc IdentificationFast Rinse Position Water meter Checking the brine draw and refill functionControl valve diagram Systems diagram General Electric Parts Catalog Parts ListProduct not accessible to provide required service What Is Not CoveredFor The Period We Will Replace Warrantor General Electric Company. Louisville, KYOne Year GE Water Softening System Warranty. For Customers in CanadaParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio