GE 215C1044P010-3 owner manual Mounting Bracket to Cabinet Wall, Inserted to avoid leaks

Page 7

Mounting Bracket to Cabinet Wall

The bracket can be used as a template for marking the location of the mounting screws. When determining the location of the bracket make sure you leave 1-1⁄2 ″ to 2″ of free area under the sumps to allow for sump removal and enough space on either side to make the tubing connections.

Tubing Connections—Compression Style

(Models GX1S04C and GN1S04C)

1 Run the length of 3⁄8″ tubing, connected to the bottom of faucet,

to the filter system outlet. Allow enough slack in the tubing so the unit can be easily removed for filter changes. Measure and cut the end of the tubing square.

2 Slide a compression nut onto the end of the tubing and push a tubing insert into the tubing.

3 Connect the tubing and tighten the compression nuts securely.

4 Repeat the preceding steps to connect a length of tubing between the filter system inlet and the water supply/saddle valve (illustration in the Installation Overview section).

2-3⁄4

 

 

Tubing connector

 

(outlet)

Mounting

 

bracket

 

Tubing connector

Mounting

(inlet)

screws

Sump

 

1 -1⁄2 to 2

Tubing Connections—Push-In Style (Model GX1S15C [rev. 2])

1 Run the length of the 3⁄8″ tubing, connected to the bottom of the faucet, to the filter system outlet (illustration above). Allow enough slack in the tubing so that the unit can be easily removed.

2 Measure and cut the end of the tubing square using a sharp cutter or knife. Remove any burrs (illustration A).

3 Inspect the end of the tubing, about 1 inch, to be sure there are no imperfections. It may be necessary to cut the tubing again.

4 Mark the tubing for length of insertion. For 3/8″ OD tubing the insertion length should be approximately 3/4 of an inch. Tubing must be fully

inserted to avoid leaks.

5 DO NOT REMOVE GRAY COLLET. Push the tubing all the way into the fitting until it bottoms out. The insertion line should be hidden or barely visible (illustration B and C). Slightly pull on the tubing to verify engagement.

6 Repeat the procedure to connect the tubing between the filter system inlet and the water supply/saddle valve (illustration in the Installation Overview section).

7 To remove tubing (illustration D), depress and hold gray collet. Pull tubing to remove.

NOTE: Avoid installing the unit where the tubing is pulled at a sharp angle. This type of installation may cause the fittings to leak. If using tubing other than what is supplied, be sure it is high quality, exact size and roundness, and has a smooth surface.

A

B

C

Cut tubing square

End of tubing round and smooth, with no cuts,

nicks or flat spots (approximately 1)

Gray Collet

(DO NOT REMOVE)

Insertion line

Tubing

 

3⁄4

Tubing must

 

be fully inserted

 

 

Insert

 

to avoid leaks.

Gray Collet

 

 

(DO NOT

 

 

REMOVE)

 

 

Insertion line

3 4"

 

Insert tubing

Engagement

3/4(3/8tubing)

D

Gray Collet

Tubing

Depress gray collet

 

and pull tubing

 

to remove

7

Image 7
Contents 7239189 WaterRead and Follow this Safety Information Carefully About the water filtration system Specification guidelinesInstallation Overview Tools and Materials Required for InstallationCheck and comply with local plumbing codes as you plan Optional Home Installation Where codes permitFeed Water Supply For 1/2 OD or larger metal tubing onlyFaucet Installation Step-by-step installation instructionsInserted to avoid leaks Mounting Bracket to Cabinet WallReassemble Filter Cartridge Installation or ReplacementProcedure for flushing the GE Water Filtration system is Flush ProcedureCircumstances that may require flushing the system are Before you call for service… General Electric parts catalog Parts ListReal Life Design Studio Consumer Support GE Appliances Website Schedule ServiceParts and Accessories Register Your Appliance GE Water Filtration System WarrantyInstructions d’installation Avertissement Éliminer après Information DE Sécurité ImportanteSpécifications Description sommaire du système de filtration d’eauRecommandations importantes concernant l’installation Instructions d’installationIllustration de l’installation Source d’alimentation du filtre Configuration D’INSTALLATION PréférentielleInstallation du robinet Étapes de l’installationÊtre completement inséré pour éviter les fuites Fixation de la bride de montage sur la paroi du placardUtilisation du système de filtration de l’eau Cartouches de filtration-Installation ou remplacementCirconstances qui peuvent nécessiter un rinçage du circuit Processus de rinçageMéthode de rinçage du système de filtration GE Débit d’eau réduit Avant de contacter un dépanneur…Présence de petites Présence de bulles dansCatalogue des pièces General Electric Liste des piècesStudio de conception réaliste Service de réparationsPièces et accessories Soutien au consommateurNúmero de modelo Instrucciones de seguridadGuarde Estas Instrucciones Guía de especificaciones Acerca del sistema de filtración de aguaSumario de la instalación Instrucciones de instalaciónRecomendaciones importantes de instalación Herramientas y Materiales requeridas para la instalaciónPara un tubo OD de 1/2 o más grande solamente Línea de abastecimiento de aguaPara un tubo OD de 1/2 o más grande solamente Instalacion DE Casa Opcional donde lo permitan los códigosInstalación de llaves de agua Instrucciones de instalación paso a pasoGN1S04C Cómo montar la abrazadera en la pared del gabineteCompletamente serconectado para evitar que gotee Alineamiento y arme nuevamente Instalación o reemplazo del cartucho del filtroGEAppliances.com Procedimiento para lavarLas uniones a presión Antes de llamar para un servicioAgua tiene burbujas de Agua y está turbiaCatálogo de partes General Electric Lista de partesDe RÉF Piezas y accesorios Ayuda al Cliente Página Web de GESolicite una reparación Garantías ampliadas