Conair UGE014/0999 manual Aligning the Tank, Position the tank downstream of the extruder

Page 20

ALIGNING THE TANK

!CAUTION: To avoid personal injury or damage to the tank, you should lift and move the tank with a forklift or hoist and straps positioned at the tank’s center of gravity.

WARNING: Improper installation could result in equipment damage and severe personal injury from electrical shock .

Electrical connections should be made only by qualified personnel. This machine requires a well-grounded circuit and three-phase alternat- ing current as specified on the data plate. If the correct power supply is not available, you must install a transformer between the building sup- ply and the machine. A properly sized conduc- tive ground wire from the power supply must be connected to the ground terminal on the tank.

1 Position the tank downstream of the extruder.

Place the tank inline with the extruder. Set the tank’s v-groove casters on the v-rails, if present.

2 Adjust the height of the tank to match the extrud- er’s centerline height. Use a level and turn the hand wheels to adjust height at both ends of the tank.

3 Adjust the horizontal (side-to-side) position of the tank. If you have the horizontal adjustment option, turn the handwheel to align the unit with other compo- nents in the extrusion line. Use a plumb bob or laser to guide the alignment.

3-4

INSTALLATION

Water/Spray Tanks

UGE014/0999

Image 20
Contents Page Date Manual Number UGE014/0999 Serial numbers Model numbers Table of Contents IntroductionPage Introduction Your Responsibility AS a User Purpose User GuideHOW Guide is Organized Read this SO no ONE Gets Hurt Page Description What is TANK?HOW IT Works Specifications Tank StyleFeatures OptionsFeatures and Options CON Closed Water Recirculation System Option Features and Options CON Installation Unpacking the Boxes Preparing for Installation Make sure the installation area providesAligning the Tank Position the tank downstream of the extruderConnecting Main Power Connecting Water AIR Supplies Connecting a ChillerTesting the Installation Page Operation Determine the cooling mode you will use Preparing forOperation Make sure the extruder and puller are readyPreparing for Operation Thread the extrudate through the tankStart the other equipment in the extrusion line StartingStopping Maintenance Preventative Maintenance Schedule Weekly, or as often as neededLubricating Tank Components Cleaning Tank Spray BarsReplacing Gaskets Open the electrical enclosure. a safety device Inspect the wires and connections. Look forInspect the exterior power cords. Carefully Checking Electrical ConnectionsTroubleshooting Before Beginning FEW WordsProduct Quality Problems Possible cause SolutionPage WE’RE Here to Help From outside the United States, callEquipment Guarantee Performance Warranty Warranty Limitations

Water/Spray Tanks, UGE014/0999 specifications

The Conair UGE014/0999 is a highly efficient water and spray tank system designed for various industrial applications, particularly in the realm of plastics processing and manufacturing. This solution stands out for its advanced features, robust construction, and user-friendly operation, making it a valuable asset for any plant seeking to enhance productivity and ensure the quality of its output.

One of the primary features of the Conair UGE014/0999 is its sizable tank capacity. Designed to hold substantial volumes of water, it enables continuous operation without the need for frequent refilling. This characteristic is especially advantageous in processes that require sustained cooling or moisture application, such as in cooling hot molds or maintaining optimal conditions for plastic products.

In terms of technologies, the Conair UGE014/0999 incorporates state-of-the-art pumping and spraying mechanisms that provide reliable and consistent performance. The system is outfitted with precision-engineered pumps capable of delivering uniform spray patterns, ensuring that the application of water is even and effective. This enhances the quality of the finished products while minimizing waste.

Another significant characteristic of the UGE014/0999 is its robust construction. Made from high-quality materials, this water and spray tank is designed to withstand the rigors of industrial environments. Its corrosion-resistant design not only extends its lifespan but also requires less maintenance, making it a cost-effective solution for manufacturers.

The ease of operation is another highlight of the Conair UGE014/0999. The tank is designed with user-friendly controls, allowing operators to easily adjust settings according to specific processing requirements. This flexibility ensures that the system can be tailored to meet the demands of varying production scenarios, thus increasing efficiency.

Furthermore, safety is a paramount consideration in the design of the Conair UGE014/0999. It features built-in safety mechanisms to prevent leaks and spills, protecting both the equipment and the working environment. This focus on safety is essential in any industrial setting, where the potential for accidents can have serious implications.

In conclusion, the Conair UGE014/0999 water and spray tank represents a perfect blend of advanced technology, robust construction, and user-friendly design. With its large capacity, efficient spraying capabilities, and safety features, it stands as a reliable choice for industries needing effective moisture management in their processes, ultimately contributing to enhanced production quality and efficiency.