BEFORE BEGINNING

You can avoid most problems by following the recommended installation, operation and maintenance procedures outlined in this User Guide. If you do have a problem, this section will help you determine what caused it and tell you how to fix it.

Before you begin troubleshooting:

Find the wiring, plumbing and assembly diagrams that were shipped with your equipment.

These diagrams are the best reference for correcting a prob- lem. The diagrams also will note any custom features, such as special wiring, control or plumbing options, not covered in this User Guide.

Verify that you have all instructional materials related to the WT/ST tank. Additional details about

troubleshooting and repairing specific components of the tank, including pumps and heat exchanger can be found in the man- ufacturers manuals included in this instruction packet.

Verify that you have manuals for equipment located upstream of the tank on the extrusion line.

Solving problems related to extrudate quality may require troubleshooting malfunctions or incorrect operating proce- dures on other pieces of equipment in the extrusion line.

A FEW WORDS

!

WARNING: This machines should be

OF CAUTION

 

adjusted and serviced only by qualified

 

technical personnel who are familiar with

construction and operation of this type of equipment.

DANGER: Voltage hazard.

Troubleshooting the electrical system of this equipment requires use of precision electronic measuring equipment, as well as access to the electrical enclosure while power is on. Exposure to potentially fatal voltage levels is unavoidable. These troubleshooting procedures should be performed only by qualified electrical technicians who know how to use this precision electronic equipment and who understand the hazards involved.

6-2

TROUBLESHOOTING

Water/Spray Tanks

UGE014/0999

Image 34
Contents Page Date Manual Number UGE014/0999 Serial numbers Model numbers Table of Contents IntroductionPage Introduction HOW Guide is Organized Purpose User GuideYour Responsibility AS a User Read this SO no ONE Gets Hurt Page Description What is TANK?HOW IT Works Specifications Tank StyleFeatures OptionsFeatures and Options CON Closed Water Recirculation System Option Features and Options CON Installation Unpacking the Boxes Preparing for Installation Make sure the installation area providesAligning the Tank Position the tank downstream of the extruderConnecting Main Power Connecting Water AIR Supplies Connecting a ChillerTesting the Installation Page Operation Operation Determine the cooling mode you will usePreparing for Make sure the extruder and puller are readyPreparing for Operation Thread the extrudate through the tankStopping StartingStart the other equipment in the extrusion line Maintenance Preventative Maintenance Schedule Weekly, or as often as neededReplacing Gaskets Cleaning Tank Spray BarsLubricating Tank Components Inspect the exterior power cords. Carefully Open the electrical enclosure. a safety deviceInspect the wires and connections. Look for Checking Electrical ConnectionsTroubleshooting Before Beginning FEW WordsProduct Quality Problems Possible cause SolutionPage WE’RE Here to Help From outside the United States, callEquipment Guarantee Performance Warranty Warranty Limitations

Water/Spray Tanks, UGE014/0999 specifications

The Conair UGE014/0999 is a highly efficient water and spray tank system designed for various industrial applications, particularly in the realm of plastics processing and manufacturing. This solution stands out for its advanced features, robust construction, and user-friendly operation, making it a valuable asset for any plant seeking to enhance productivity and ensure the quality of its output.

One of the primary features of the Conair UGE014/0999 is its sizable tank capacity. Designed to hold substantial volumes of water, it enables continuous operation without the need for frequent refilling. This characteristic is especially advantageous in processes that require sustained cooling or moisture application, such as in cooling hot molds or maintaining optimal conditions for plastic products.

In terms of technologies, the Conair UGE014/0999 incorporates state-of-the-art pumping and spraying mechanisms that provide reliable and consistent performance. The system is outfitted with precision-engineered pumps capable of delivering uniform spray patterns, ensuring that the application of water is even and effective. This enhances the quality of the finished products while minimizing waste.

Another significant characteristic of the UGE014/0999 is its robust construction. Made from high-quality materials, this water and spray tank is designed to withstand the rigors of industrial environments. Its corrosion-resistant design not only extends its lifespan but also requires less maintenance, making it a cost-effective solution for manufacturers.

The ease of operation is another highlight of the Conair UGE014/0999. The tank is designed with user-friendly controls, allowing operators to easily adjust settings according to specific processing requirements. This flexibility ensures that the system can be tailored to meet the demands of varying production scenarios, thus increasing efficiency.

Furthermore, safety is a paramount consideration in the design of the Conair UGE014/0999. It features built-in safety mechanisms to prevent leaks and spills, protecting both the equipment and the working environment. This focus on safety is essential in any industrial setting, where the potential for accidents can have serious implications.

In conclusion, the Conair UGE014/0999 water and spray tank represents a perfect blend of advanced technology, robust construction, and user-friendly design. With its large capacity, efficient spraying capabilities, and safety features, it stands as a reliable choice for industries needing effective moisture management in their processes, ultimately contributing to enhanced production quality and efficiency.