Conair Water/Spray Tanks, UGE014/0999 manual Connecting Main Power

Page 21

WARNING: Improper installation could result in equipment damage and severe personal injury from electrical shock .

Electrical connections should be made only by qualified personnel. This machine requires a well-grounded circuit and three-phase alternat- ing current as specified on the data plate. If the correct power supply is not available, you must install a transformer between the building sup- ply and the machine. A properly sized conduc- tive ground wire from the power supply must be connected to the ground terminal on the tank.

Electrical connections are required only on WT/ST tanks with the optional water recirculation system and/or heat exchanger.

Always refer to the wiring diagrams that came with your tank before making electrical connections. The diagrams show the minimum size main power cable required for you tank, and the most accurate electrical component information. The pro- cedure for making electrical connections willy vary according to the options ordered with the tank.

Generally, you should:

1

 

Disconnect and lock out the incoming main

 

 

 

 

power source.

 

 

 

 

 

 

 

Open the electrical enclosure.

2

 

 

 

 

 

3

 

Connect the power and ground wires to the

 

 

 

 

terminals indicated on the wiring diagram that came with

 

 

 

 

your machine.

 

 

 

Check every terminal screw to make sure wires are

4

 

 

 

 

 

secure. Gently tug each wire. If a wire is loose, use a

 

 

 

 

screwdriver to tighten the terminal.

CONNECTING

THE MAIN

POWER

UGE014/0999

Water/Spray Tanks

INSTALLATION 3-5

Image 21
Contents Page Date Manual Number UGE014/0999 Serial numbers Model numbers Introduction Table of ContentsPage Introduction Purpose User Guide HOW Guide is OrganizedYour Responsibility AS a User Read this SO no ONE Gets Hurt Page Description TANK? What isHOW IT Works Tank Style SpecificationsOptions FeaturesFeatures and Options CON Closed Water Recirculation System Option Features and Options CON Installation Unpacking the Boxes Make sure the installation area provides Preparing for InstallationPosition the tank downstream of the extruder Aligning the TankConnecting Main Power Connecting a Chiller Connecting Water AIR SuppliesTesting the Installation Page Operation Preparing for Determine the cooling mode you will useOperation Make sure the extruder and puller are readyThread the extrudate through the tank Preparing for OperationStarting StoppingStart the other equipment in the extrusion line Maintenance Weekly, or as often as needed Preventative Maintenance ScheduleCleaning Tank Spray Bars Replacing GasketsLubricating Tank Components Inspect the wires and connections. Look for Open the electrical enclosure. a safety deviceInspect the exterior power cords. Carefully Checking Electrical ConnectionsTroubleshooting FEW Words Before BeginningPossible cause Solution Product Quality ProblemsPage From outside the United States, call WE’RE Here to HelpWarranty Limitations Equipment Guarantee Performance Warranty

Water/Spray Tanks, UGE014/0999 specifications

The Conair UGE014/0999 is a highly efficient water and spray tank system designed for various industrial applications, particularly in the realm of plastics processing and manufacturing. This solution stands out for its advanced features, robust construction, and user-friendly operation, making it a valuable asset for any plant seeking to enhance productivity and ensure the quality of its output.

One of the primary features of the Conair UGE014/0999 is its sizable tank capacity. Designed to hold substantial volumes of water, it enables continuous operation without the need for frequent refilling. This characteristic is especially advantageous in processes that require sustained cooling or moisture application, such as in cooling hot molds or maintaining optimal conditions for plastic products.

In terms of technologies, the Conair UGE014/0999 incorporates state-of-the-art pumping and spraying mechanisms that provide reliable and consistent performance. The system is outfitted with precision-engineered pumps capable of delivering uniform spray patterns, ensuring that the application of water is even and effective. This enhances the quality of the finished products while minimizing waste.

Another significant characteristic of the UGE014/0999 is its robust construction. Made from high-quality materials, this water and spray tank is designed to withstand the rigors of industrial environments. Its corrosion-resistant design not only extends its lifespan but also requires less maintenance, making it a cost-effective solution for manufacturers.

The ease of operation is another highlight of the Conair UGE014/0999. The tank is designed with user-friendly controls, allowing operators to easily adjust settings according to specific processing requirements. This flexibility ensures that the system can be tailored to meet the demands of varying production scenarios, thus increasing efficiency.

Furthermore, safety is a paramount consideration in the design of the Conair UGE014/0999. It features built-in safety mechanisms to prevent leaks and spills, protecting both the equipment and the working environment. This focus on safety is essential in any industrial setting, where the potential for accidents can have serious implications.

In conclusion, the Conair UGE014/0999 water and spray tank represents a perfect blend of advanced technology, robust construction, and user-friendly design. With its large capacity, efficient spraying capabilities, and safety features, it stands as a reliable choice for industries needing effective moisture management in their processes, ultimately contributing to enhanced production quality and efficiency.