Conair UGE014/0999, Water/Spray Tanks manual Connecting Water AIR Supplies, Connecting a Chiller

Page 22

CONNECTING

THE WATER AND

AIR SUPPLIES

The standard WT.ST tanks are designed for use with city, tower or chilled water supplies. You may choose to treat the water to prevent algae build-up.

WARNING: Do not use deionized water, brine or other corrosive water mixtures for the main water supply unless your tank has been specially designed for such mixtures. Consult a water treatment special- ist for the best way to prevent algae build-up without damaging the equipment.

1

Connect the main water supply to the 11/2-inch

 

NPT fitting on the tank.

 

Connect the compressed air supply to the fitting

2

 

on the tank air wipe compartment.

CONNECTING A CHILLER

You can connect a chiller to the tank’s optional heat exchang- er to remove heat from the extrudate more efficiently. Typically, the tank comes with the 3/4 inch lines of the stan- dard tube and shell heater plumbed to the tank’s water mani- fold. The 11/2 inch inlet and outlet of the heat exchanger can be used for the chiller.

TIP: If you have a water supply with high mineral content, connect the chiller to the tube ends of the heat exchanger.

For maximum water flow:

Connect the chiller “To Process” and “From Process” lines to the largest NPT fittings in the shell of the heat exchanger.

To water manifold

From chiller

To chiller

From water

pump

For maximum cooling efficiency:

Connect the chiller “To Process” and “From Process” lines to the smallest NPT tube ends of the heat exchanger.

To chiller

From water pump

To water manifold

From chiller

3-6

INSTALLATION

Water/Spray Tanks

UGE014/0999

Image 22
Contents Page Date Manual Number UGE014/0999 Serial numbers Model numbers Table of Contents IntroductionPage Introduction HOW Guide is Organized Purpose User GuideYour Responsibility AS a User Read this SO no ONE Gets Hurt Page Description What is TANK?HOW IT Works Specifications Tank StyleFeatures OptionsFeatures and Options CON Closed Water Recirculation System Option Features and Options CON Installation Unpacking the Boxes Preparing for Installation Make sure the installation area providesAligning the Tank Position the tank downstream of the extruderConnecting Main Power Connecting Water AIR Supplies Connecting a ChillerTesting the Installation Page Operation Operation Determine the cooling mode you will usePreparing for Make sure the extruder and puller are readyPreparing for Operation Thread the extrudate through the tankStopping StartingStart the other equipment in the extrusion line Maintenance Preventative Maintenance Schedule Weekly, or as often as neededReplacing Gaskets Cleaning Tank Spray BarsLubricating Tank Components Inspect the exterior power cords. Carefully Open the electrical enclosure. a safety deviceInspect the wires and connections. Look for Checking Electrical ConnectionsTroubleshooting Before Beginning FEW WordsProduct Quality Problems Possible cause SolutionPage WE’RE Here to Help From outside the United States, callEquipment Guarantee Performance Warranty Warranty Limitations

Water/Spray Tanks, UGE014/0999 specifications

The Conair UGE014/0999 is a highly efficient water and spray tank system designed for various industrial applications, particularly in the realm of plastics processing and manufacturing. This solution stands out for its advanced features, robust construction, and user-friendly operation, making it a valuable asset for any plant seeking to enhance productivity and ensure the quality of its output.

One of the primary features of the Conair UGE014/0999 is its sizable tank capacity. Designed to hold substantial volumes of water, it enables continuous operation without the need for frequent refilling. This characteristic is especially advantageous in processes that require sustained cooling or moisture application, such as in cooling hot molds or maintaining optimal conditions for plastic products.

In terms of technologies, the Conair UGE014/0999 incorporates state-of-the-art pumping and spraying mechanisms that provide reliable and consistent performance. The system is outfitted with precision-engineered pumps capable of delivering uniform spray patterns, ensuring that the application of water is even and effective. This enhances the quality of the finished products while minimizing waste.

Another significant characteristic of the UGE014/0999 is its robust construction. Made from high-quality materials, this water and spray tank is designed to withstand the rigors of industrial environments. Its corrosion-resistant design not only extends its lifespan but also requires less maintenance, making it a cost-effective solution for manufacturers.

The ease of operation is another highlight of the Conair UGE014/0999. The tank is designed with user-friendly controls, allowing operators to easily adjust settings according to specific processing requirements. This flexibility ensures that the system can be tailored to meet the demands of varying production scenarios, thus increasing efficiency.

Furthermore, safety is a paramount consideration in the design of the Conair UGE014/0999. It features built-in safety mechanisms to prevent leaks and spills, protecting both the equipment and the working environment. This focus on safety is essential in any industrial setting, where the potential for accidents can have serious implications.

In conclusion, the Conair UGE014/0999 water and spray tank represents a perfect blend of advanced technology, robust construction, and user-friendly design. With its large capacity, efficient spraying capabilities, and safety features, it stands as a reliable choice for industries needing effective moisture management in their processes, ultimately contributing to enhanced production quality and efficiency.