Bradley Smoker MG-2/BIR3 installation instructions 23/07 Bradley Corporation 215-1510 Rev. D ECN

Page 6

Express® Lavatory System - MG Series with Battery Infrared Control

 

MG-2/BIR3

Installation Instructions

TAS - Texas Accessibility

 

 

 

CENTERLINE OF FIXTURE

 

Standards:

 

 

 

 

 

Juvenile Height (grades

 

25-1/2" (648)

 

25-1/2" (648)

 

Pre-K thru 5 or 6)

 

APPROX. DIMENSION

 

APPROX. DIMENSION

1-1/2" NPT DRAIN

 

 

14"

 

14"

 

 

 

STUB OUT 2"

 

 

(356)

 

(356)

 

 

 

 

 

 

4"

 

4" (102)

 

 

 

(102)

 

 

 

 

 

4"

 

 

 

 

A

(102)

 

A

 

 

 

 

 

 

 

B

B

B

 

 

 

H

C

 

 

 

 

 

 

 

24-3/4"

 

 

 

 

 

(629)

28"

 

B

B

B

 

(711)

 

22-1/4"

22-1/2"

 

 

 

 

(565)

(572)

 

 

 

 

21"

 

 

 

 

 

 

 

 

 

 

(533)

 

 

 

 

16"

 

 

 

 

 

(406)

 

 

 

 

 

FLOOR

 

 

 

1/2" NPT HOT AND COLD SUPPLIES OR TEMPERED SUPPLY – STUB OUT 2"

Figure 1a

 

3/8" WALL ANCHORS (8) PLACES

MIN. PULL-OUT STRENGTH 1000 LBS. PER ANCHOR

TAS - Texas Accessibility

 

 

 

CENTERLINE OF FIXTURE

 

Standards:

 

 

 

 

 

Juvenile Height (grades 6

 

25-1/2" (648)

 

25-1/2" (648)

 

thru 8 or 9)

 

APPROX. DIMENSION

 

APPROX. DIMENSION

1-1/2" NPT DRAIN

 

 

14"

 

14"

 

 

 

STUB OUT 2"

 

 

(356)

 

(356)

 

 

 

 

 

 

4"

 

4" (102)

 

 

 

(102)

 

 

 

 

 

4"

 

 

 

 

A

(102)

 

A

 

 

 

 

 

 

 

B

B

B

 

 

 

H

C

 

 

 

 

 

 

 

26-3/4"

30"

 

 

 

 

(679)

(762)

 

B

B

B

24-1/4"

 

 

24-1/2"

 

 

 

 

(616)

 

 

 

 

 

(622)

 

 

 

 

23"

 

 

 

 

 

(584)

 

 

 

 

18"

 

 

 

 

 

(457)

 

 

 

 

 

FLOOR

 

 

 

1/2" NPT HOT AND COLD SUPPLIES OR TEMPERED SUPPLY – STUB OUT 2"

Figure 1b

 

3/8" WALL ANCHORS (8) PLACES

MIN. PULL-OUT STRENGTH 1000 LBS. PER ANCHOR

6

 

8/23/07

 

Bradley Corporation • 215-1510 Rev. D; ECN 07-815

Image 6
Contents Installation Instructions Table of ContentsPre-Installation Information MG-2/BIR3 Express Lavatory System Dimensions Dimensions Installation Instructions Rough in supplies and optional hot water heater23/07 Bradley Corporation 215-1510 Rev. D ECN Rough in wall anchors Mount frame to wall Install bowl assembly Do not overtightenHot Connecting electrical and supply tubing Counterclockwise to increaseStainless Steel Access Panel cleaning Cleaning and Maintenance InstructionsTerreon and panel maintenance Terreon Bowl, Sprayhead and Pedestal End Cap cleaningAssembly of Components Other replacement partsSensor assembly and solenoid valve access Infrared Window Sprayhead Body NUT Troubleshooting BIR3 Components Solution Remove debris between diaphragm and the valve seatSolenoid Valve S07-072 closed body and S07-072A thru body Thermostatic Mixing Valve Maintenance and Troubleshooting Problem Limited water flowProblem External leaks in the system Vernatherm Thermostatic Mixing Valve S01-524 Repair Kit S65-259