Step 5: Connecting supply

1.Loosen but do not remove the two mounting screws holding the valve bracket to the frame. Slide the valve bracket up until the larger cutout in the frame’s slot aligns with the screw head (see Figure 5b). Then lift up to remove the valve bracket from the frame.

2.FOR HOT AND COLD SUPPLY: Attach the stop/check to the hot and cold water supply piping from the wall. Connect the flexible hoses to the Vernatherm™ Mixing Valve and to the stop/checks (see Figure 5a).

NOTE: The “H” on Vernatherm™ Mixing Valve indicates hot water supply inlet.

FOR SINGLE TEMPERED SUPPLY: Attach the stop/check to the 1/2" tempered supply line. Connect the stop/check to the tempered line adapter with the flexible supply hose (Figure 5c).

3.Assemble the P-trap by connecting the 1-1/2" tubular pipe to the tailpiece and to the 1-1/2" drain pipe stubbed out of the wall.

4.Install the strainer on the drain plug opening inside the bowl, and push the strainer firmly into place. Secure the stainer with the screw provided.

Hot and

Cold

FLEXIBLE

Supplies

SUPPLY

 

HOSE

CONNECT TO 1/2" NPT HOT WATER SUPPLY

Vernatherm™

 

THERMOSTATIC

CONNECT TO

MIXING VALVE

 

1/2" NPT COLD

 

WATER SUPPLY

FLEXIBLE SUPPLY

HOSE

Figure 5a

VALVE BRACKET

MOUNTING SCREW

SLOT IN

FRAME

Figure 5b

Single

Tempered

Supply

Figure 5c

FLEXIBLE SUPPLY HOSE (TO SOLENOID BRACKET)

TEMPERED

TO SUPPLY LINE

LINE ADAPTER

 

(S39-685)

 

10

8/23/07

Bradley Corporation • 215-1510 Rev. D; ECN 07-815

Image 10
Contents Installation Instructions Table of ContentsPre-Installation Information MG-2/BIR3 Express Lavatory System Dimensions Dimensions Installation Instructions Rough in supplies and optional hot water heater23/07 Bradley Corporation 215-1510 Rev. D ECN Rough in wall anchors Mount frame to wall Install bowl assembly Do not overtightenHot Connecting electrical and supply tubing Counterclockwise to increaseStainless Steel Access Panel cleaning Cleaning and Maintenance InstructionsTerreon and panel maintenance Terreon Bowl, Sprayhead and Pedestal End Cap cleaningAssembly of Components Other replacement partsSensor assembly and solenoid valve access Infrared Window Sprayhead Body NUT Troubleshooting BIR3 Components Solution Remove debris between diaphragm and the valve seatSolenoid Valve S07-072 closed body and S07-072A thru body Problem Limited water flow Thermostatic Mixing Valve Maintenance and TroubleshootingProblem External leaks in the system Vernatherm Thermostatic Mixing Valve S01-524 Repair Kit S65-259