Bradley Smoker MG-2/BIR3 Vernatherm Thermostatic Mixing Valve S01-524, Repair Kit S65-259

Page 19

 

Express® Lavatory System - MG Series with Battery Infrared Control

Installation Instructions

MG-2/BIR3

 

 

Vernatherm™ Thermostatic Mixing Valve (S01-524)

Repair Kit S65-259

Item

Qty

Description

 

 

 

5

1

Thermostat

7

1

O-Ring

8

1

O-Ring

Strainer 11 (173-028)

10 Nut 3/8-24 Hex Jam

9 Cap

8 O-Ring

7 O-Ring

6 Stem

5 Thermostat

4 Piston

3 Spring

2 Seal Cup

1 Valve Body

Figure 14

Tempered Line Adapter Assembly (S39-685) Option

Figure 15

Strainer

 

173-028

Bradley Corporation • 215-1510 Rev. D; ECN 07-815

8/23/07

19

Image 19
Contents Table of Contents Installation InstructionsPre-Installation Information MG-2/BIR3 Express Lavatory System Dimensions Dimensions Rough in supplies and optional hot water heater Installation Instructions23/07 Bradley Corporation 215-1510 Rev. D ECN Rough in wall anchors Mount frame to wall Do not overtighten Install bowl assemblyHot Counterclockwise to increase Connecting electrical and supply tubingTerreon Bowl, Sprayhead and Pedestal End Cap cleaning Cleaning and Maintenance InstructionsTerreon and panel maintenance Stainless Steel Access Panel cleaningOther replacement parts Assembly of ComponentsSensor assembly and solenoid valve access Infrared Window Sprayhead Body NUT Solution Remove debris between diaphragm and the valve seat Troubleshooting BIR3 ComponentsSolenoid Valve S07-072 closed body and S07-072A thru body Problem Limited water flow Thermostatic Mixing Valve Maintenance and TroubleshootingProblem External leaks in the system Repair Kit S65-259 Vernatherm Thermostatic Mixing Valve S01-524