Bradley Smoker MG-2/BIR3 installation instructions Rough in wall anchors

Page 7

 

Express® Lavatory System - MG Series with Battery Infrared Control

Installation Instructions

MG-2/BIR3

 

 

Installation Instructions continued . . .

Step 2: Rough in wall anchors

1.Install six 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the locations marked (ref. location “B” shown in Figure 1, 1a or 1b on pages 5-6).

NOTE: The dimensions for the wall anchors at location “A” are for reference only.

2.On the back of the bowl, measure the distance between the 3/4" bowl mounting holes. Divide this measurement in half. Measure and mark this dimension on the wall to the left of the centerline and to the right of the centerline. Install two 3/8" wall anchors with a minimum pull- out rating of 1,000 lbs. (supplied by installer) at the locations marked (ref. location “A” shown in Figure 1, 1a or 1b on pages 5-6).

NOTE: The anchors will be used to mount the Express® MG-2/BIR3 bowl and frame to the wall.

1/2" NPT HOT AND COLD SUPPLIES OR TEMPERED SUPPLY.

STUB OUT 2"

1-1/2" NPT DRAIN STUB OUT 2"

Figure 2

Bradley Corporation • 215-1510 Rev. D; ECN 07-815

8/23/07

7

Image 7
Contents Table of Contents Installation InstructionsPre-Installation Information MG-2/BIR3 Express Lavatory System Dimensions Dimensions Rough in supplies and optional hot water heater Installation Instructions23/07 Bradley Corporation 215-1510 Rev. D ECN Rough in wall anchors Mount frame to wall Do not overtighten Install bowl assemblyHot Counterclockwise to increase Connecting electrical and supply tubingTerreon Bowl, Sprayhead and Pedestal End Cap cleaning Cleaning and Maintenance InstructionsTerreon and panel maintenance Stainless Steel Access Panel cleaningOther replacement parts Assembly of ComponentsSensor assembly and solenoid valve access Infrared Window Sprayhead Body NUT Solution Remove debris between diaphragm and the valve seat Troubleshooting BIR3 ComponentsSolenoid Valve S07-072 closed body and S07-072A thru body Problem Limited water flow Thermostatic Mixing Valve Maintenance and TroubleshootingProblem External leaks in the system Repair Kit S65-259 Vernatherm Thermostatic Mixing Valve S01-524