Bradley Smoker MG-2/BIR3 installation instructions Sensor assembly and solenoid valve access

Page 14

Express® Lavatory System - MG Series with Battery Infrared Control

 

MG-2/BIR3

Installation Instructions

Assembly of Components continued . . .

Sensor assembly and solenoid valve access

• To access solenoids:

Using a 5/32" Allen socket wrench, loosen, but do not remove the bottom three access panel screws. Remove the two top access panel screws and washers securing the panel to the frame and remove the access panel (see Figure 3 on page 8). Solenoids are located on left side of frame (see Figure 9).

To remove sprayhead:

Remove (3) bolts located underside of bowl neck (see Figures 8 and 10). Carefully remove sprayhead from bowl.

To access sprayhead/aerator/lens and sensor assembly:

Remove (2) screws and washers from the access plate assembly using a 1/8" Allen socket wrench. The access plate assembly is located underneath the sprayhead (2) places (see Figure 11a on page 15), the assembly will drop down to access the lens, sensor, and sensor eyes, housing flow control and tube connector.

FRAME

5/16" I.D. BRAIDED HOSE

VERNATHERM™

MIXING VALVE

Figure 9

SOLENOIDS

 

 

 

 

SPRAYHEAD AERATOR

 

 

SPRAYHEAD BODY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASSEMBLY S05-166

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOUNTING LOCATION

 

 

 

 

Figure 10

 

 

 

TO BOWL (3) PLACES

 

 

 

 

 

14

8/23/07

Bradley Corporation • 215-1510 Rev. D; ECN 07-815

Image 14
Contents Installation Instructions Table of ContentsPre-Installation Information MG-2/BIR3 Express Lavatory System Dimensions Dimensions Installation Instructions Rough in supplies and optional hot water heater23/07 Bradley Corporation 215-1510 Rev. D ECN Rough in wall anchors Mount frame to wall Install bowl assembly Do not overtightenHot Connecting electrical and supply tubing Counterclockwise to increaseStainless Steel Access Panel cleaning Cleaning and Maintenance InstructionsTerreon and panel maintenance Terreon Bowl, Sprayhead and Pedestal End Cap cleaningAssembly of Components Other replacement partsSensor assembly and solenoid valve access Infrared Window Sprayhead Body NUT Troubleshooting BIR3 Components Solution Remove debris between diaphragm and the valve seatSolenoid Valve S07-072 closed body and S07-072A thru body Problem External leaks in the system Thermostatic Mixing Valve Maintenance and TroubleshootingProblem Limited water flow Vernatherm Thermostatic Mixing Valve S01-524 Repair Kit S65-259