Maytag W10112419D, 99043751D Calculating Vent System Length, Cm Vent System, Example vent system

Page 6

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

6" (15.2 cm) Vent System

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

90° elbow

5.0 ft

 

(1.5 m)

3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System

Vent Piece

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

90° elbow

(1.5 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

12.0 ft

flat elbow

(3.7 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

0.0 ft

wall cap

(0.0 m)

6" (15.2 cm)

0.0 ft

wall cap

(0.0 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

4.5 ft

to 6" (15.2 cm)

(1.4 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

to 6" (15.2 cm) 90° elbow

(1.5 m)

Example vent system

3¹⁄₄" x 10"

 

(8.3 x 25.4 cm)

 

elbow

Wall cap

6 ft (1.8 m)

2ft

(0.6 m)

Example vent system

90˚ elbows

3¼" x 10"

(8.3 x 25.4 cm) to 6" (15.2 cm) transition

6 ft

(1.8 m)

2 ft (0.6 m)

Wall cap

1

- 90° elbow

= 5.0 ft (1.5 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

1

- wall cap

= 0.0 ft (0.0 m)

 

 

Length of 3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

= 13.0 ft (3.9 m)

system

 

1

- transition

= 4.5 ft (1.4 m)

2

- 90° elbows

= 10.0 ft (3.0 m)

1

- wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

 

 

Length of 6" (15.2 cm) system

= 22.5 ft (6.9 m)

6

Image 6
Contents Range Hood Range Hood Safety Table of ContentsImportant Safety Instructions Installation Requirements Tools and PartsLocation Requirements Venting Requirements Cabinet DimensionsCold Weather Installations Makeup Air¹⁄₄ x 10 8.3 cm x 25.4 cm Vent System Calculating Vent System LengthCm Vent System Example vent systemElectrical Requirements Installation InstructionsDetermine Wiring Hole Location Prepare LocationWall Venting To wire through topTo wire through rear wall To make a 4 x 10½ 10.2 cm x 26.7 cm rectangle in the wallInstall Range Hood For vented model installations onlyFor Power Supply Installations Make Electrical Connection Complete InstallationRange Hood USE Range Hood ControlsU.S.A CleaningRange Hood Care CanadaWhirlpool Corporation Major Appliance Warranty This limited warranty does not coverSécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Exigences Dinstallation Exigences demplacementOutillage et pièces Air dappoint Installations pour régions à climat froidExigences concernant l’évacuation Méthodes dévacuationSystème de décharge de 6 15,2 cm Spécifications électriquesCalcul de la longueur du circuit dévacuation Système de décharge de 3¹⁄₄ x 10 8,3 cm x 25,4 cmDéterminer lemplacement du trou de passage du câble Instructions DinstallationPréparation de lemplacement PréparationCm x 25,4 cm Décharge à travers le toit Décharge à travers le murCâblage à travers le mur arrière Installation de la hotte Soulever la hotte sous le placard et déterminer sa positionCouverte Raccordement électrique Achever linstallationInstaller une lampe à incandescence de 75 watts maximum Raccordement par câblage directEntretien DE LA Hotte Commandes de la hotte de cuisinièreUtilisation DE LA Hotte DE Cuisinière NettoyageAu Canada Assistance OU ServiceGarantie DES Gros Appareils Ménagers Whirlpool Corporation Si vous avez besoin de pièces de rechangeW10112419D