Maytag W10112419D, 99043751D Wall Venting, To wire through top, To wire through rear wall

Page 8

2.To wire through top:

Mark a line 7½" (19.0 cm) from the right of the centerline on the underside of the cabinet. Mark the point on this line that is 2" (5.0 cm) from back wall. Drill a 1¼" (3.0 cm) diameter hole through the cabinet at this point.

7 ¹⁄₂"

2" (5.1 cm)

from wall,

(19 cm)

not cabinet

 

 

frame

Centerline

To wire through rear wall:

Mark a line 7½" (19.0 cm) from the right of the centerline on the wall. Mark the point on this line that is ¾" (1.9 cm) from underside of cabinet. Drill a 1¼" (3.0 cm) diameter hole through wall at this point.

³⁄₄" (1.9 cm)

7 ¹⁄₂"

(19 cm)

Centerline

Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm) Rectangular Vent System

Roof Venting

To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangular cutout on the underside of cabinet top and bottom:

1.Mark lines 1½" (3.8 cm) and 5½" (14 cm) from the back wall on the centerline of the underside of cabinet.

2.Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the underside of cabinet.

3.Use saber or keyhole saw to cut a rectangular opening for vent.

4.Repeat steps 1-3 for the underside of the top of the cabinet.

Cabinet cutouts

 

 

*1¹/₂" (3.8 cm)

*5¹/₂"

 

5¹/₄"

(14 cm)

(13.3 cm)

 

 

 

 

5¹/₄"

 

(13.3 cm)

*From wall, not cabinet frame

Wall Venting

To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangle in the wall:

1.Make 2 lines by measuring from floor 65⁷⁄₈" (167.3 cm) and 62³⁄₈" (158.4 cm) or ¹⁄₈" (3.2 mm) and 3⁵⁄₈" (9.2 cm) down from underside of cabinet and mark on the centerline on the back wall.

2.Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the wall.

3.Use saber or keyhole saw to cut a rectangular opening in the wall for the vent.

Centerline

Cabinet

front

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

¹⁄₈"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3.2 mm)

 

 

 

 

 

 

 

 

 

⁵⁄₈"

 

 

 

 

 

 

 

3

 

 

 

 

 

5 ¹⁄₄"

(9.2 cm)

 

 

 

 

(13.3 cm)

 

 

 

 

 

 

Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm) Rectangular Vent to 6" (15.2 cm) Round Vent Transition

Roof Venting

To make a 4" x 10½" (10.2 x 26.7 cm) rectangular cutout on the underside of cabinet bottom:

1.Mark lines 1½" (3.8 cm) and 5½" (14 cm) from the back wall on the centerline of the underside of cabinet.

2.Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the underside of cabinet.

3.Use saber or keyhole saw to cut a rectangular opening for

vent.

*1¹/₂" (3.8 cm)

*5¹/₂"

(14 cm) 5¹/₄"

5¹/₄" (13.3 cm)

(13.3 cm)

*From wall, not cabinet frame

To make a 6¹⁄₄" (15.9 cm) circle on the underside of the cabinet top:

1.Mark a centerline on the underside of the top of cabinet.

2.Mark a line 4³⁄₄" (12.1 cm) from the back wall on the underside of the top of cabinet.

3.Draw a circle using a compass or 6¹⁄₄" (15.9 cm) circle template.

8

Image 8
Contents Range Hood Range Hood Safety Table of ContentsImportant Safety Instructions Location Requirements Installation RequirementsTools and Parts Cabinet Dimensions Cold Weather InstallationsVenting Requirements Makeup AirCalculating Vent System Length Cm Vent System¹⁄₄ x 10 8.3 cm x 25.4 cm Vent System Example vent systemInstallation Instructions Determine Wiring Hole LocationElectrical Requirements Prepare LocationTo wire through top To wire through rear wallWall Venting To make a 4 x 10½ 10.2 cm x 26.7 cm rectangle in the wallFor Power Supply Installations Install Range HoodFor vented model installations only Complete Installation Range Hood USEMake Electrical Connection Range Hood ControlsCleaning Range Hood CareU.S.A CanadaWhirlpool Corporation Major Appliance Warranty This limited warranty does not coverSécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Outillage et pièces Exigences DinstallationExigences demplacement Installations pour régions à climat froid Exigences concernant l’évacuationAir dappoint Méthodes dévacuationSpécifications électriques Calcul de la longueur du circuit dévacuationSystème de décharge de 6 15,2 cm Système de décharge de 3¹⁄₄ x 10 8,3 cm x 25,4 cmInstructions Dinstallation Préparation de lemplacementDéterminer lemplacement du trou de passage du câble PréparationCâblage à travers le mur arrière Cm x 25,4 cm Décharge à travers le toitDécharge à travers le mur Couverte Installation de la hotteSoulever la hotte sous le placard et déterminer sa position Achever linstallation Installer une lampe à incandescence de 75 watts maximumRaccordement électrique Raccordement par câblage directCommandes de la hotte de cuisinière Utilisation DE LA Hotte DE CuisinièreEntretien DE LA Hotte NettoyageAssistance OU Service Garantie DES Gros Appareils Ménagers Whirlpool CorporationAu Canada Si vous avez besoin de pièces de rechangeW10112419D