INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

Drill

1¹⁄₄" (3.0 cm) drill bit

¹⁄₈" (3.0 mm) drill bit for pilot holes

Pencil

Wire stripper or utility knife

Tape measure or ruler

Caulking gun and weatherproof caulking compound

Flat-blade screwdriver

Phillips screwdriver

Saber or keyhole saw

Metal snips

Compass or 8" (20.3 cm) circle template

Parts supplied

Remove parts from package. Check that all parts are included.

2 - 3.5 x 9.5 mm screws

3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent damper

T-10®Torx®† adapter

4 - 4.5 x 13 mm mounting screws

Parts needed

1 - 75W max, 120V incandescent light bulb

Wall or roof cap with damper to match vent system

3 - UL listed wire connectors

Vent clamps/duct tape as required

For cabinets with recessed bottoms:

Two 2" (5.1 cm) wide filler strips. Length and thickness determined by recess dimensions.

Four flat head wood screws or machine screws with washers and nuts (to attach filler strips)

For 7" (17.8 cm) round vented installations:

7" (17.8 cm) round metal vent system

7" (17.8 cm) round damper. For information on ordering, see the “Accessories” section.

7" (17.8 cm) round vent mounting plate. For information on ordering, see the “Accessories” section.

For 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vented installations:

3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular metal vent system

For non-vented (recirculation) installations:

Charcoal filter kit. For information on ordering, see the “Accessories” section.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the left wall.

Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance. Consult the cooktop/range manufacturer installation instructions before making any cutouts.

Grounded electrical outlet is required. See “Electrical Requirements” section.

All openings in ceiling and wall where range hood will be installed must be sealed.

These range hoods are factory set for vented installations. Models that are capable of being installed as non-vented (recirculating) require charcoal filters. See the “Accessories” section to order charcoal filter kit.

For Mobile Home Installations

The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title

24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.

Product Dimensions

 

6⁹⁄₁₆" (16.7 cm) or

 

2"

9⁹⁄₁₆" (24.4 cm)

 

(5.1 cm)

 

 

 

1"

 

 

(2.5 cm)

4¹⁵⁄₁₆"

⁷⁄₈"

 

(12.5 cm)

 

(2.2 cm)

9"

 

 

 

(22.9 cm)

 

29¹⁵⁄₁₆" (76.0 cm) or

1¹⁄₂"

 

35¹⁵⁄₁₆" (91.0 cm)

(3.8 cm) 18⁵⁄₈"

 

 

(47.3 cm)

†®TORX and T10 are registered trademarks of Acument Intellectual Properties, LLC.

4

Image 4
Contents Hotte D’ASPIRATION DE Range Hood Safety Table of ContentsImportant Safety Instructions Tools and Parts Installation RequirementsLocation Requirements Installation Clearances Cold Weather InstallationsVenting Requirements Makeup AirCalculating Vent System Length Cm Round Vent SystemExample vent system ¹⁄₄ x 10 8.3 cm x 25.4 cm Vent SystemInstallation Instructions Determine Wiring Hole LocationElectrical Requirements Prepare LocationTo wire through top To wire through wallWall Venting To make a 3½ x 10½ 8.9 cm x 26.7 cm rectangle in the wallInstall Vent System Install Range HoodStyle 3 Cut Openings for 7 17.8 cm Round Vent Round vent knockout Rectangular vent knockout Damper Flap Removal for 3¼ x 10 8.3 x 25.4 cm Vent Connector Power Supply Cable InstallationComplete Installation Make Electrical ConnectionCleaning Range Hood USERange Hood Care Range Hood ControlsWiring Diagram For non-vented recirculating installationsReplacing the Incandescent Light Bulb To replace filterAssistance or Service AccessoriesU.S.A CanadaWhirlpool Major Appliance Limited Warranty Sécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Exigences demplacement Exigences DinstallationOutils et pièces Installations dans les régions au climat froid Exigences concernant l’évacuationDistances de dégagement à respecter Air d’appointMéthodes d’évacuation Calcul de la longueur du circuit d’évacuationSystème dévacuation avec conduits ronds de 7 17,8 cm Exemple de circuit d’évacuationLongueur maximale recommandée = 35 pi 10,7 m Spécifications électriquesCircuit dévacuation de 3¹⁄₄ x 10 8,3 cm x 25,4 cm ComposantInstructions D’INSTALLATION Préparation de lemplacementDéterminer l’emplacement du trou de passage du câble Câblage à travers le sommet du placardÉvacuation par le mur Installation de la hotte Installation du conduit d’évacuationPlaque de protection pour mode recyclage Vis Installation du cordon dalimentation Raccordement électriqueAchever l’installation Commandes de la hotte de cuisinièreUtilisation DE LA Hotte Pour faire fonctionner la lampeInstallations sans décharge à lextérieur recyclage Remplacement de lampoule à incandescenceEntretien DE LA Hotte NettoyageSchéma DE Câblage Marche Arrêt Arrêt Faible ÉlevéAssistance OU Service Au Canada AccessoiresW10400322F