Whirlpool UXT4230AY Wiring Diagram, For non-vented recirculating installations, To replace filter

Page 14

For non-vented (recirculating) installations:

The charcoal filter is not washable. It should last up to 6 months with normal use.

1.Replace metal grease filter with a charcoal filter. For information on ordering, see the “Accessories” section.

To replace filter:

1.Remove screw from the grease filter retainer.

2.Turn the grease filter retainer to release filter.

3.Reinstall the filter by placing the back edge in the channel at rear of hood. Push filter into place, turn the filter retainer to secure filter to range hood.

4.Replace screw in the grease filter retainer.

Replacing the Incandescent Light Bulb

Turn off the range hood and allow the light bulb to cool.

1.Disconnect power.

2.Squeeze the plastic lens cover and remove it from the hood.

A B

A. Light bulb socket

B. Lens cover

3.Screw light bulb into socket.

4.Replace lens cover by squeezing cover and inserting tabs into slots.

5.Reconnect power.

If new light does not operate, make sure the lamp is inserted correctly before calling service.

WIRING DIAGRAM

Motor Switch

Off - On

BK

RD

BK

RD

WH

NOTE: Speed 1 not used

Speed 2

Common

Speed 1

 

C25

 

 

 

BK

WH

RD

 

Motor Characteristics

 

Power Supply

 

120 VAC

 

Frequency

 

60 Hz

 

Amperage

 

1.2 ±10% A

BK

Wattage Rating

 

73 ±10% Watts

 

 

 

Motor Resistance

 

White - Red

 

17.1 ±10% Ohms

L

White - Black

 

13.6 ±10% Ohms

Lamp Switch

 

 

 

Off1

- Low 2- High

 

 

Lamp Switch

L

 

3

 

Operation

 

 

1 - 2

Off

 

 

1 - 3

Low

 

 

 

1 - L

High

 

 

 

 

RD

YL

Rectifier

 

 

 

 

Diode

 

 

 

BK

WH

Ground

Screw

WH

SE114A

NGND

14

Image 14
Contents Hotte D’ASPIRATION DE Range Hood Safety Table of ContentsImportant Safety Instructions Location Requirements Installation RequirementsTools and Parts Venting Requirements Installation ClearancesCold Weather Installations Makeup AirExample vent system Calculating Vent System LengthCm Round Vent System ¹⁄₄ x 10 8.3 cm x 25.4 cm Vent SystemElectrical Requirements Installation InstructionsDetermine Wiring Hole Location Prepare LocationWall Venting To wire through topTo wire through wall To make a 3½ x 10½ 8.9 cm x 26.7 cm rectangle in the wallStyle 3 Cut Openings for 7 17.8 cm Round Vent Install Range HoodInstall Vent System Round vent knockout Rectangular vent knockout Damper Flap Removal for 3¼ x 10 8.3 x 25.4 cm Vent Connector Power Supply Cable InstallationComplete Installation Make Electrical ConnectionRange Hood Care CleaningRange Hood USE Range Hood ControlsReplacing the Incandescent Light Bulb Wiring DiagramFor non-vented recirculating installations To replace filterU.S.A Assistance or ServiceAccessories CanadaWhirlpool Major Appliance Limited Warranty Sécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Outils et pièces Exigences DinstallationExigences demplacement Distances de dégagement à respecter Installations dans les régions au climat froidExigences concernant l’évacuation Air d’appointSystème dévacuation avec conduits ronds de 7 17,8 cm Méthodes d’évacuationCalcul de la longueur du circuit d’évacuation Exemple de circuit d’évacuationCircuit dévacuation de 3¹⁄₄ x 10 8,3 cm x 25,4 cm Longueur maximale recommandée = 35 pi 10,7 mSpécifications électriques ComposantDéterminer l’emplacement du trou de passage du câble Instructions D’INSTALLATIONPréparation de lemplacement Câblage à travers le sommet du placardÉvacuation par le mur Installation de la hotte Installation du conduit d’évacuationPlaque de protection pour mode recyclage Vis Installation du cordon dalimentation Raccordement électriqueUtilisation DE LA Hotte Achever l’installationCommandes de la hotte de cuisinière Pour faire fonctionner la lampeEntretien DE LA Hotte Installations sans décharge à lextérieur recyclageRemplacement de lampoule à incandescence NettoyageSchéma DE Câblage Marche Arrêt Arrêt Faible ÉlevéAssistance OU Service Au Canada AccessoiresW10400322F