Electrolux E15IM60E manual Drain Pump Connection, Connecting a Drain Pump

Page 9

10Drain Pump Connection

CONNECTING A DRAIN PUMP

If a gravity drain connection is not available, and you have not purchased the E15IM60E with factory installed pump, we strongly recommend the use of the Electrolux EIMP60 drain pump. The Electrolux EIMP60 drain pump is available through your Dealer, or direct from Electrolux with complete installation instructions. If a pump other than the Electrolux EIMP60 drain pump is to be used, it must meet the following specifications:

It must be UL listed and have a UL listed, 120 VAC, 3-wire grounded power cord.

It must have overall maximum outside dimensions of 8-3/4" wide x 5-3/4" deep x 7-3/4" high.

It must have a minimum flow rate of 15 gallons per hour at 10 feet of lift.

It must have a sealed sump which does not allow water leakage in the case of a power outage, restricted drain or pump failure.

It must have a check valve in the discharge line to prevent waste water return to the pump.

It must have an overflow protection control which will shut off power to the ice maker in the event of a pump failure.

It must have an operating temperature range of 50°F to 110°F (10°C to 43°C).

!CAUTION

In the event of a power outage, restricted drain or pump failure, the failure to use the Electrolux EIMP60 drain pump or a pump with the above listed specifications, could result in substantial water leakage and pooling with severe and costly water damage and related consequential damages and harm.

Image 9
Contents Use & Care Guide Finding Information Please Read and Save this GuideMake a Record for Quick Reference QUESTIONS? Product Registration CardImportant Safety Instructions SafetySafety Precautions DefinitionsGeneral Precautions Installation Dimensions InstallationInstalling the Drain Drain InstallationIce Makers With Factory Installed Drain Pump Gravity DrainBack View Drain Pump Connection Connecting a Drain PumpPreparing the Site Site PreparationCabinet Or Wall Door Swing Clearance Needed Water Supply Connection Connecting the Water SupplyUL134 Leveling the Unit LevelingReversing the Door Some Models Door ReversalHinge Screw PIN DoorAdjustment Adjusting the DoorTo adjust Door Closers Boss Table of Contents Installing a BUILT-IN Built-In InstallationInitial START-UP Start-upOperation Normal OperationIce Cube Thickness ICE Dispenser Operation & Care Sample Area Maintaining and Cleaning Your Icemaker MaintenanceExterior Cleaning As Required Special ConsiderationsDo not Clean with Steel Wool Pads Interior Cleaning As RequiredCondenser Cleaning Every 3 Months Self Cleaning Every 6 Months Inlet Screen Cleaning Every Year Draining for NON-USE Storage, Vacation and MovingTroubleshooting Before YOU Call for ServiceTroubleshooting Guide Problem Possible Cause Remedy If Service is RequiredPeriod WE will Responsible for Full ONE-YEAR Warranty Information