Wolf W302210I installation instructions E P 4 R E AT TA C H R O U G H I N P L AT E

Page 11

I N S TA L L AT I O N I N S T R U C T I O N S

L OW- P RO F I L E A N D 2 4 " ( 6 1 0 ) H O O D S

Separate the transition from the rough-in plate by removing the four shipping screws. Do not discard the screws; they will be needed to reinstall the transition to the rough-in plate.

Determine the direction of discharge for your installation and rotate the back panel accordingly. The wall hood back panel has been designed to accommodate a vertical or horizontal discharge.

Horizontal discharge is only applicable on low-profile wall hoods (excluding W302210I and W362210I) used with a remote blower.

Horizontal discharge is applicable on 24"

(610)deep wall hoods used with WBLOWER- 60INT, WBLOWER-120INT or any Wolf remote blower.

In-line blowers and WBLOWER-90INT are not for use in horizontal discharge applications.

Use the rough-in plate assembly to deter- mine the location of wall studs. Position the rough-in plate in the desired location and mark the predrilled mounting holes on the wall.

For horizontal discharge, the electrical box will need to be moved so that it is in the upper right-hand corner of the rough-in plate when attached to the wall.

Horizontal discharge requires a wall cut-out. Refer to the illustrations below. The location of the cut-out is determined by the installa- tion height of the hood.

If you are installing an in-line or remote blower, drill a 7/8" (22) hole through the wood framing for the conduit. Refer to the in-line and remote blower information on pages 18–19 and follow installation instruc- tions provided with the blower.

IMPORTANT NOTE: Do not run wiring for the remote blower through the ductwork.

S T E P 4 : R E AT TA C H R O U G H - I N P L AT E

Reattach the transition to the rough-in plate using the four shipping screws removed previously.

Position the studs on the rough-in plate into the slots on the hood. Use the hex head nuts (included with the hood) to secure the hood assembly to the rough-in plate.

Reinstall the shipping screws removed previously from the top and back of the rough-in plate.

IMPORTANT NOTE: If additional support is required, drill supplementary mounting holes in the rough-in plate and use these holes to attach the hood assembly to the wall framing.

 

Wall Cut-Out Area

 

 

17" (432)

 

41/2" (114)

 

411/16" (119)

4" (102)

8" (203)

Transition

 

 

 

 

 

Centerline

Hood Centerline

Wall cut-out for low-profile hoods – horizontal discharge

Dimensions in parentheses are in millimeters unless otherwise specified.

Wall Cut-Out Area

 

21" (533)

101/4"

513/16"

(148)

(260)

 

 

Transition

 

Centerline

Hood Centerline

Wall cut-out for 24" (610) deep hoods – horizontal discharge

11

Image 11
Contents Installation Instructions N TA C T F O R M AT I O N Wolf Customer Service Website Wolfappliance.comS T O F M AT E R I a L S S TA L L AT I O N R E Q U I R E M E N T SC T C O V E R Installation C O N S I D E R AT I O N SC E S S O R I E S E C T R I C a L R E Q U I R E M E N T S6 8 6 D E E P WA L L H O O D S W- P R O F I L E WA L L H O O D S6 1 0 D E E P WA L L H O O D S 27 686 Deep Wall Hoods Installation S P E C I F I C AT I O N SLow-Profile 24 610 Deep Wall Hoods 27 686 Deep Wall Hoods Model Low-Profile Wall Hoods Model24 610 Deep Wall Hoods Model Ducting options for low-profile wall hoods E P 1 I N S TA L L D U C T W O R K To reduce the risk of fire, use only metal ductwork Ducting options for 24 610 deep wall hoods S TA L L AT I O N I N S T R U C T I O N SIf wall framing is not available, wall anchors must be used Rough-in plate/transition assemblyE P 2 WA L L P R E PA R AT I O N E P 3 H O O D P R E PA R AT I O NWall cut-out for 24 610 deep hoods horizontal discharge E P 4 R E AT TA C H R O U G H I N P L AT EWall cut-out for low-profile hoods horizontal discharge M P L E T E T H E I N S TA L L AT I O N Hood installationE P 5 I N S TA L L T H E H O O D 27 686 Deep WA L L H O O D S Mounting holes for 27 686 hoods Rough-in plate installationE P 4 I N S TA L L R O U G H I N P L AT E E P 6 I N S TA L L W I R I N G P O RTA N T N OT EPRO Wall V E N T I L AT I O N H O O D S T E R N a L B L O W E R I N S TA L L AT I O N Internal blower installationO W E R I N S TA L L AT I O N Dimensions for BLOWER-60IL Dimensions for BLOWER-110ILLine a N D Remote B L O W E R S O W E R W I R I N G Dimensions for BLOWER-90REMDimensions for BLOWER-120REM Dimensions for BLOWER-150REMM OT E B L O W E R S Blower a S S E M B L I E ST E R N a L B L O W E R S L I N E B L O W E R SFilter and grease cup installation Duct cover installationRO U B L E S H O O T I N G YO U N E E D ServiceNameplate I N S TA L L AT I O N Page 9 3 4 0 0