Wolf W302210I E P 5 I N S TA L L T H E H O O D, M P L E T E T H E I N S Ta L L At I O N

Page 12

W O L F PRO WALL VENTILATION H O O D S

LOW- PROFILE A N D 24" (610) H O O D S

S T E P 5 : I N S TA L L T H E H O O D

IMPORTANT NOTE: If a backsplash is to be used, it should be installed before the wall hood is mounted.

Align the hood assembly with the marked location.

Install the #10 x 2" (59) screws (included with the hood) through the mounting holes on the rough-in plate. Verify that the screws engage the wall studs or framing. If not, wall anchors must be used.

Attach the transition to existing ductwork with sheet metal screws and duct sealing tape.

C O M P L E T E T H E I N S TA L L AT I O N

To complete the installation for the low-profile and 24" (610) deep wall hoods, follow Step 6: Install Wiring and refer to information on pages 17–19 for internal, in-line and remote blowers.

Follow instructions to install the filters and grease cups on page 21. If you will be attach- ing the Wolf logo nameplate, follow the steps on page 22.

Due to the weight of the hood, be sure to have adequate manpower for installation.

Soffit

Rough-In Plate

Mounting Holes

Hood installation

12

Image 12
Contents Installation Instructions Wolf Customer Service Website Wolfappliance.com N TA C T F O R M AT I O NS TA L L AT I O N R E Q U I R E M E N T S S T O F M AT E R I a L SInstallation C O N S I D E R AT I O N S C E S S O R I E SE C T R I C a L R E Q U I R E M E N T S C T C O V E RW- P R O F I L E WA L L H O O D S 6 1 0 D E E P WA L L H O O D S6 8 6 D E E P WA L L H O O D S Installation S P E C I F I C AT I O N S Low-Profile 24 610 Deep Wall Hoods27 686 Deep Wall Hoods Low-Profile Wall Hoods Model 24 610 Deep Wall Hoods Model27 686 Deep Wall Hoods Model E P 1 I N S TA L L D U C T W O R K To reduce the risk of fire, use only metal ductworkDucting options for low-profile wall hoods S TA L L AT I O N I N S T R U C T I O N S Ducting options for 24 610 deep wall hoodsRough-in plate/transition assembly E P 2 WA L L P R E PA R AT I O NE P 3 H O O D P R E PA R AT I O N If wall framing is not available, wall anchors must be usedE P 4 R E AT TA C H R O U G H I N P L AT E Wall cut-out for low-profile hoods horizontal dischargeWall cut-out for 24 610 deep hoods horizontal discharge Hood installation E P 5 I N S TA L L T H E H O O DM P L E T E T H E I N S TA L L AT I O N 27 686 Deep WA L L H O O D S Rough-in plate installation Mounting holes for 27 686 hoodsE P 4 I N S TA L L R O U G H I N P L AT E P O RTA N T N OT E PRO Wall V E N T I L AT I O N H O O D SE P 6 I N S TA L L W I R I N G Internal blower installation T E R N a L B L O W E R I N S TA L L AT I O NDimensions for BLOWER-60IL Dimensions for BLOWER-110IL Line a N D Remote B L O W E R SO W E R I N S TA L L AT I O N Dimensions for BLOWER-90REM Dimensions for BLOWER-120REMDimensions for BLOWER-150REM O W E R W I R I N GBlower a S S E M B L I E S T E R N a L B L O W E R SL I N E B L O W E R S M OT E B L O W E R SDuct cover installation Filter and grease cup installationYO U N E E D Service Nameplate I N S TA L L AT I O NRO U B L E S H O O T I N G Page 9 3 4 0 0