Wolf W302210I Mounting holes for 27 686 hoods, Rough-in plate installation

Page 14

A C C E S S O R I E S

Optional acces- sories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com.

W O L F PRO WALL VENTILATION H O O D S

27" (686) DEEP WA L L H O O D S

S T E P 2 : WA L L P R E PA R AT I O N

Framing must be tied together and to ceiling joists to provide enough structural strength to support the weight of the hood and internal blower, if applicable.

Construct the wood wall framing flush with the wall studs and centered in the location that the hood will be mounted. Use the rough-in plate shipped with hood to deter- mine the location of the framing.

After the wall surface is finished, secure the rough-in plate to the wall surface.

If wall framing is not available, wall anchors must be used.

S T E P 3 : H O O D P R E PA R AT I O N

IMPORTANT NOTE: If a duct cover is to be used, follow instructions on page 21 before installing the wall hood.

Refer to the illustration below for the location of mounting holes for the 27" (686) wall hood.

The hood assembly is shipped with the rough-in plate/transition attached. The transition is shipped upside down in the top of the hood. It must be removed and rein- stalled in the proper position.

Remove the filters by pushing each filter up at the angle it is placed in, and rotate down. Remove the center filter first. Then take out the grease cups placed on the bottom edge of the hood coinciding with the bottom edge of the filters. Gloves should be worn to provide the proper grip when removing filters.

Detach the rough-in plate/transition assembly from the hood by removing the screws on the top and back of the assembly.

Separate the transition from the rough-in plate by removing the four shipping screws. Do not discard the screws, they will be needed to reinstall the transition to the rough-in plate. Refer to the illustration below.

Reattach the transition to the rough-in plate using the four shipping screws removed previously.

Attach the transition to existing ductwork with sheet metal screws and duct sealing tape.

 

 

91/2" (241)

 

211/4" (540)

10" (254)

 

 

 

 

41/2" (114)

 

 

*

 

81/2" (216)

 

 

*

 

 

*

 

 

20" (508)

41/2"

 

 

 

(114)

8"

(203)

13/16" (21)

*

 

 

 

 

*

*

41/2" (114) *

41/2"

(114)

*

*Dimension is 2" (51)

Mounting holes for 27" (686) hoods

Shipping

Rough-In

Screws

Plate

 

Transition

Rough-in plate installation

14

Image 14
Contents Installation Instructions Wolf Customer Service Website Wolfappliance.com N TA C T F O R M AT I O NS TA L L AT I O N R E Q U I R E M E N T S S T O F M AT E R I a L SE C T R I C a L R E Q U I R E M E N T S Installation C O N S I D E R AT I O N SC E S S O R I E S C T C O V E R6 8 6 D E E P WA L L H O O D S W- P R O F I L E WA L L H O O D S6 1 0 D E E P WA L L H O O D S 27 686 Deep Wall Hoods Installation S P E C I F I C AT I O N SLow-Profile 24 610 Deep Wall Hoods 27 686 Deep Wall Hoods Model Low-Profile Wall Hoods Model24 610 Deep Wall Hoods Model Ducting options for low-profile wall hoods E P 1 I N S TA L L D U C T W O R KTo reduce the risk of fire, use only metal ductwork S TA L L AT I O N I N S T R U C T I O N S Ducting options for 24 610 deep wall hoodsE P 3 H O O D P R E PA R AT I O N Rough-in plate/transition assemblyE P 2 WA L L P R E PA R AT I O N If wall framing is not available, wall anchors must be used Wall cut-out for 24 610 deep hoods horizontal discharge E P 4 R E AT TA C H R O U G H I N P L AT E Wall cut-out for low-profile hoods horizontal discharge M P L E T E T H E I N S TA L L AT I O N Hood installationE P 5 I N S TA L L T H E H O O D 27 686 Deep WA L L H O O D S Rough-in plate installation Mounting holes for 27 686 hoodsE P 4 I N S TA L L R O U G H I N P L AT E E P 6 I N S TA L L W I R I N G P O RTA N T N OT EPRO Wall V E N T I L AT I O N H O O D S Internal blower installation T E R N a L B L O W E R I N S TA L L AT I O NO W E R I N S TA L L AT I O N Dimensions for BLOWER-60IL Dimensions for BLOWER-110ILLine a N D Remote B L O W E R S Dimensions for BLOWER-150REM Dimensions for BLOWER-90REMDimensions for BLOWER-120REM O W E R W I R I N GL I N E B L O W E R S Blower a S S E M B L I E ST E R N a L B L O W E R S M OT E B L O W E R SDuct cover installation Filter and grease cup installationRO U B L E S H O O T I N G YO U N E E D ServiceNameplate I N S TA L L AT I O N Page 9 3 4 0 0