Wolf W302210I installation instructions 27 686 Deep WA L L H O O D S

Page 13

I N S TA L L AT I O N I N S T R U C T I O N S

27" (686) DEEP WA L L H O O D S

S T E P 1 : I N S TA L L D U C T W O R K

To reduce the risk of fire, use only metal ductwork.

IMPORTANT NOTE: Wolf recommends that the Pro wall ventilation hood be installed 30" (762) to 36" (914) above the countertop.

IMPORTANT NOTE: Consult a qualified HVAC Engineer for specific ducting applications.

IMPORTANT NOTE: All Wolf Pro 27" (686) deep wall hoods must exhaust to the outdoors. Always use metal ducting. Do not use flex ducting.

Decide where the ductwork will run between the hood and the outside. A straight, short duct run will allow the hood to perform more efficiently. Limit the number of elbows and transitions to as few as possible. Long duct runs, elbows and transitions will reduce the performance of the hood. Wolf recommends the maximum linear duct run be no greater than 50' (15 m). The 27" (686) deep wall hood is vertical discharge only.

Always install a roof or wall cap if you are not installing a remote blower. Connect 10" (254) round metal ductwork to the cap and work back towards the hood. Use duct sealing tape on joints between ductwork sections.

IMPORTANT NOTE: Do not use ducting smaller than 10" (254) round.

Pro wall hoods come standard with a backdraft damper included in the transition assembly. In cold weather installations a backdraft damper is necessary to minimize the backflow of cold air into the room.

Local building codes may require the use of make-up air. Consult your local HVAC profes- sional for specific requirements in your area.

 

DUCTWORK INSTALLATION

 

THROUGH ROOF

ROOF CAP OR REMOTE BLOWER

 

10" ROUND DUCT

 

 

TRANSITION

SOFFIT OR CABINET

221/4"W x 9"D TO 10" ROUND

OR DUCT COVER

10"H (INCLUDING FLANGES)

 

VERTICAL DISCHARGE

18" (457)

WALL HOOD

HEIGHT OF HOOD

 

 

27" (686)

30" TO 36"

DEPTH OF HOOD

 

(762–914)

 

COUNTERTOP

 

TO BOTTOM OF

 

VENTILATION HOOD

 

36" (914)

 

STANDARD

 

FLOOR TO

 

COUNTERTOP

 

HEIGHT

 

VERTICAL DISCHARGE ONLY FOR 27" (686) DEEP WALL HOODS.

Ducting options for 27" (686) deep wall hoods

To reduce the risk of fire and electric shock, install this ventilation hood only with a blower manufactured by Wolf. Blower model numbers are listed on page 20.

Dimensions in parentheses are in

 

millimeters unless otherwise specified.

13

Image 13
Contents Installation Instructions N TA C T F O R M AT I O N Wolf Customer Service Website Wolfappliance.comS T O F M AT E R I a L S S TA L L AT I O N R E Q U I R E M E N T SC E S S O R I E S Installation C O N S I D E R AT I O N SE C T R I C a L R E Q U I R E M E N T S C T C O V E R6 1 0 D E E P WA L L H O O D S W- P R O F I L E WA L L H O O D S6 8 6 D E E P WA L L H O O D S Low-Profile 24 610 Deep Wall Hoods Installation S P E C I F I C AT I O N S27 686 Deep Wall Hoods 24 610 Deep Wall Hoods Model Low-Profile Wall Hoods Model27 686 Deep Wall Hoods Model To reduce the risk of fire, use only metal ductwork E P 1 I N S TA L L D U C T W O R KDucting options for low-profile wall hoods Ducting options for 24 610 deep wall hoods S TA L L AT I O N I N S T R U C T I O N S E P 2 WA L L P R E PA R AT I O N Rough-in plate/transition assembly E P 3 H O O D P R E PA R AT I O N If wall framing is not available, wall anchors must be usedWall cut-out for low-profile hoods horizontal discharge E P 4 R E AT TA C H R O U G H I N P L AT EWall cut-out for 24 610 deep hoods horizontal discharge E P 5 I N S TA L L T H E H O O D Hood installationM P L E T E T H E I N S TA L L AT I O N 27 686 Deep WA L L H O O D S Mounting holes for 27 686 hoods Rough-in plate installationE P 4 I N S TA L L R O U G H I N P L AT E PRO Wall V E N T I L AT I O N H O O D S P O RTA N T N OT EE P 6 I N S TA L L W I R I N G T E R N a L B L O W E R I N S TA L L AT I O N Internal blower installationLine a N D Remote B L O W E R S Dimensions for BLOWER-60IL Dimensions for BLOWER-110ILO W E R I N S TA L L AT I O N Dimensions for BLOWER-120REM Dimensions for BLOWER-90REMDimensions for BLOWER-150REM O W E R W I R I N GT E R N a L B L O W E R S Blower a S S E M B L I E SL I N E B L O W E R S M OT E B L O W E R SFilter and grease cup installation Duct cover installationNameplate I N S TA L L AT I O N YO U N E E D ServiceRO U B L E S H O O T I N G Page 9 3 4 0 0