PRODUCT DATA SHEETS
Base Grille Water Filtration System Model WF-NL300/NL300
Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead.
Capacity: 300 Gallons (1136 Liters)
Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance |
| Average | Maximum | Average | Minimum % | Average % | NSF Test |
Reduction |
| Influent | Effluent | Effluent | Reduction | Reduction | Number |
|
|
|
|
|
|
|
|
Chlorine, Taste/Odor |
| 2.0 mg/L | N/A | 0.1 mg/L | N/A | 95% | 981788 |
|
|
|
|
|
|
|
|
Contaminant | U.S. EPA | Average | Maximum | Average | Minimum% | Average% | NSF Test |
Reduction | MCL | Influent | Effluent | Effluent | Reduction | Reduction | Number |
Performance** |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lead: @ pH 6.5 | 0.015 mg/L | 0.16 mg/L* | 0.007 mg/L | 0.005 mg/L | 95% | 97% | 976115 |
Lead: @ pH 8.5 | 0.015 mg/L | 0.14 mg/L* | 0.012 mg/L | 0.008 mg/L | 91% | 94% | 976116 |
Base Grille Water Filtration System Model WF-L500/L500
Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead.
Capacity: 500 Gallons (1893 Liters)
Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance |
| Average | Maximum | Average | Minimum % | Average % | NSF Test |
Reduction |
| Influent | Effluent | Effluent | Reduction | Reduction | Number |
|
|
|
|
|
|
|
|
Chlorine, Taste/Odor |
| 2.0 mg/L | N/A | 0.1 mg/L | N/A | 95% | 981788 |
|
|
|
|
|
|
|
|
Contaminant | U.S. EPA | Average | Maximum | Average | Minimum% | Average% | NSF Test |
Reduction | MCL | Influent | Effluent | Effluent | Reduction | Reduction | Number |
Performance** |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lead: @ pH 6.5 | 0.015 mg/L | 0.16 mg/L* | 0.007 mg/L | 0.005 mg/L | 95% | 97% | 976115 |
Lead: @ pH 8.5 | 0.015 mg/L | 0.14 mg/L* | 0.012 mg/L | 0.008 mg/L | 91% | 94% | 976116 |
|
|
|
|
|
|
|
|
■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
■Model
■Model
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
■Refer to the “Assistance or Service” section for the Manufacturer’s name, address and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well | |
Water Pressure | 30 - 120 psi | (207 - 827 kPa) |
Water Temperature | 33° - 100°F | (0.6° - 37.8° C) |
*Test requirement is 0.15 mg/L ± 10%.
**These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ® NSF is a registered trademark of NSF International.
26