KitchenAid LI3ZFE/W10321799F Make Electrical Connection, Non-Vented Recirculating Installation

Page 8

Non-Vented (Recirculating) Installation

1.Attach the air deflector to the upper horizontal support using 4 mounting screws.

B

A

B

A.Deflector

B.Mounting screws

2.Measure the length of 6" (15.2 cm) duct needed to connect the transition to the deflector.

NOTE: Vent should fit up inside the deflector 1" (2.5 cm) minimum.

3.Install vent between the transition and the deflector.

NOTE: To make vent installation easier, temporarily remove the deflector from the chimney support bracket and replace after vent section is in place.

4.Seal all connections with vent clamps.

Make Electrical Connection

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.Remove terminal box cover.

3.Remove the knockout in the terminal box and install a UL listed or CSA approved ¹⁄₂" strain relief.

A B

C

4.Run home power supply cable through strain relief, into terminal box.

A B

C

D

EF

A.Home power supply cable

B.UL listed or CSA approved strain relief

C.Black wires

D.UL listed wire connectors

E.White wires

F. Green (or bare) and yellow-green ground wires

5.Use UL listed wire connectors and connect black wires (C) together.

6.Use UL listed wire connectors and connect white wires (E) together.

WARNING

Electrical Shock Hazard

Electrically ground blower.

Connect ground wire to green and yellow ground wire in terminal box.

Failure to do so can result in death or electrical shock.

7.Connect green (or bare) ground wire from home power supply to yellow-green ground wire (F) in terminal box using UL listed wire connectors.

8.Tighten strain relief screw.

9.Install terminal box cover.

10.Check that all light bulbs are secure in their sockets.

11.Reconnect power.

A.Knockout

B.Terminal box

C.Terminal box cover

8

Image 8
Contents Island Canopy Range Hood Table DES Matières Table of ContentsRange Hood Safety Installation Requirements For Vented Installations, You Will Also NeedTools and Parts Tools NeededFor Mobile Home Installations Product DimensionsInstallation Dimensions Location RequirementsVenting Requirements Installation Instructions Range Hood Mounting Screws InstallationElectrical Requirements Prepare LocationConnect Vent System Assemble and Install Range HoodComplete Preparation Non-Vented Recirculating Installation Make Electrical ConnectionInstall Duct CoversComplete Installation Range Hood USETimer DisplayLight Fan SpeedCleaning Range Hood CareWiring Diagram Motor SpecificationsAssistance or Service AccessoriesU.S.A CanadaKitchenaid Ventilation Warranty This limited warranty does not coverSécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Outils et pièces Exigences D’INSTALLATIONExigences d’emplacement Dimensions du produit Dimensions d’installationInstallations dans une région à climat froid Exigences concernant l’évacuationSpécifications électriques Instructions D’INSTALLATION Préparation de l’emplacementInstallation des vis de montage de la hotte Terminer la préparationAssemblage et installation de la hotte Raccordement du circuit d’évacuationRaccordement électrique Installation des cache-conduits Achever l’installationTableau de commande Utilisation DE LA HotteAffichage ÉclairageMinuterie Vitesse du ventilateurEntretien DE LA Hotte NettoyageSchéma DE Câblage Caractéristiques du moteurAu Canada Assistance OU ServiceAccessoires W10321799F Garantie DU Système DE Ventilation KitchenaidLa présente garantie limitée ne couvre pas