Weber 89795 manual Wash hands after handling this product, Liquid Propane GAS Units only

Page 2

2

DANGERS & WARNINGS

DANGER

Failure to follow the Dangers, Warnings and Cautions contained in this Owner’s Manual may result in serious bodily injury or death, or in a fire or an explosion causing damage to property.

WARNINGS

Do not store a spare or disconnected liquid propane cylinder under or near this barbecue. Improper assembly may be dangerous. Please follow the assembly instructions carefully.

After a period of storage, and/or nonuse, the Weber® gas barbecue should be checked for gas leaks and burner obstructions before use. See instructions in this manual for correct procedures.

Do not operate the Weber® gas barbecue if there is a gas leak present. Do not use a flame to check for gas leaks.

Combustible materials should never be within 24 inches (61 cm) of the back or sides of your Weber® gas barbecue. Do not put a barbecue cover or anything flammable on, or in the storage area under the barbecue.

Your Weber® gas barbecue should never be used by children. Accessible parts of the barbecue may be very hot. Keep young children away while it is in use.

You should exercise reasonable care when operating your Weber® gas barbecue. It will be hot during cooking or cleaning and should never be left unattended, or moved while in operation.

Should the burners go out while in operation, turn all gas valves off. Open the lid and wait five minutes before attempting to relight, using the lighting instructions.

Do not use charcoal or lava rock in your Weber® gas barbecue.

Never lean over open grill or place hands or fingers on the front edge of the cooking box. Should a grease fire occur, turn off all burners and leave lid closed until fire is out.

Do not enlarge valve orifices or burner ports when cleaning the valves or burners. The Weber® gas barbecue should be thoroughly cleaned on a regular basis.

Liquid propane gas is not natural gas. The conversion or attempted use of natural gas in a liquid propane unit or liquid propane gas in a natural gas unit is dangerous and will void your warranty.

Do not attempt to disconnect any gas fitting while your barbecue is in operation. Use heat-resistant barbecue mitts or gloves when operating barbecue.

Keep any electrical supply cord and the fuel supply hose away from any heated surfaces.

Combustion byproducts produced when using this product contain chemicals known to the state of California to cause cancer, birth defects, or other reproductive harm.

Do not use this barbecue unless all parts are in place. The unit must be properly assembled according to the assembly instructions.

Proposition 65 Warning: Handling the brass material on this product exposes you to lead, a chemical known to the state of California to cause cancer, birth defects or other reproductive harm.

(Wash hands after handling this product.)

LIQUID PROPANE GAS UNITS ONLY:

Use the pressure regulator and hose assembly that is supplied with your Weber® gas barbecue.

Do not attempt to disconnect the gas regulator and hose assembly or any gas fitting while your barbecue is in operation.

A dented or rusty liquid propane cylinder may be hazardous and should be checked by your liquid propane supplier. Do not use a liquid propane cylinder with a damaged valve.

Although your liquid propane cylinder may appear to be empty, gas may still be present, and the cylinder should be transported and stored accordingly.

If you see, smell or hear the hiss of escaping gas from the liquid propane cylinder:

1.Move away from liquid propane cylinder.

2.Do not attempt to correct the problem yourself.

3.Call your fire department.

WWW.WEBER.COM®

Image 2
Contents #89795 Wash hands after handling this product Liquid Propane GAS Units onlyOperating GAS Supply Testing WARRANTY3Warranty StorageSide Burner BUILT-IN Structure Cutout DimensionsGAS Instructions Locating Your BUILT-IN Side BurnerBUILT-IN GAS Line Locations GAS InstructionsGAS Line Locations Test ConnectionsGAS Line Piping Typical Natural GAS Supply InstallationGeneral Specifications for Piping Connect GAS Supply Side Burner Lighting Instructions Lighting the Side BurnerIgniter Operating / MaintenanceManually Lighting the Side Burner To ExtinguishSide Burner Maintenance Side Burner TroubleshootingProblem Check Cure Para SU Seguridad Advertencias Peligros Y AdvertenciasPeligro Únicamente Unidades DE GAS Propano LicuadoAlmacenaje GARANTÍA13Garantía OperaciónQuemador Lateral Dimensiones DE Corte DEL EmpotramientoInstrucciones Para EL GAS Ubicación DEL Quemador Lateral EmpotradoUbicaciones DE LAS Líneas DE GAS Empotradas Instrucciones Para EL GASUbicaciones DE LA Línea DE GAS Pruebe LAS Conexiones16INSTRUCCIONES Para EL GAS Especificaciones Generales Para LA TuberíaConectar EL Suministro DE GAS Conexiones DE Suministro DE GAS Natural AL Quemador LateralPrueba DE LA Conexión DEL GAS Natural Instrucciones Para Encender EL Quemador Lateral PeligroEncendido DEL Quemador Lateral Encendedor Operación /MANTENIMIENTOEncendido Manual DEL Quemador Lateral Peligro Reemplace LAS Baterías DEL EncendedorMantenimiento DEL Quemador Lateral Resolución DE Problemas CON EL Quemador LateralProblema Revisar Remedio CES Accessoires Sont Vendus Separement Mises EN Garde Appareils a GAZ Propane UniquementStockage GARANTIE23Garantie UtilisationLocalisation DU Bruleur Lateral Dimensions Pour LE Decoupage DE LA Structure EncastreeInstructions Relatives AU GAZ Bruleur LateralLocalisations DES Conduites DE GAZ Encastrees Instructions Relatives AU GAZLocalisations DES Conduites DE GAZ Test DES ConnexionsGeneralites Concernant LES Canalisations Installation D’ARRIVEE DE GAZ Naturel TypiqueCanalisations DE GAZ Test DES Raccords Raccordement DE L’ARRIVEE DE GAZInstructions Pour L’ALLUMAGE DU Bruleur Lateral Allumage DU Bruleur LateralPour Eteindre UTILISATION/MAINTENANCE29Allumage Manuel DU Bruleur Lateral AllumeurDepannage DU Bruleur Lateral Probleme Verification SolutionMaintenance DU Bruleur Lateral Page WEBER-STEPHEN Products CO