Weber 89795 manual Side Burner Lighting Instructions, Lighting the Side Burner

Page 8

8

GAS INSTRUCTIONS

 

 

Check:

1)Corrugated gas line-to-Accessory “T” Connection.

2)Main gas Supply to regulator

WARNING: If there is a leak a connection(1), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact informa- tion sheet provided with your manual.

Check:

When leak checks are complete, turn gas supply OFF at the source and rinse connec- tions with water.

(1) a.

(2)

b.

c.

SIDE BURNER LIGHTING INSTRUCTIONS

DANGER

Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

LIGHTING THE SIDE BURNER

1)Open the side burner lid.

2)Check that the side burner valve is turned OFF. (Push the knob down and turn clockwise to ensure it is in the off position.).

3)Turn the gas supply valve on.

4)Push down and turn the side burner control valve to START/HI.

5)Push igniter button and hold until burner ignites. You will hear the igniter sparking.

CAUTION: Side burner flame may be difficult to see on a bright sunny day.



 



WARNING: If the side burner does not light:

1)Turn OFF the side burner control valve.

2)Wait 5 minutes to let the gas clear before you try again or try to light with a match.

a

b

c

NG CONNECTION TEST

Top View

To SIde Burner

To Regulator

WWW.WEBER.COM®

Image 8
Contents #89795 Wash hands after handling this product Liquid Propane GAS Units onlyWARRANTY3 WarrantyOperating GAS Supply Testing StorageBUILT-IN Structure Cutout Dimensions GAS InstructionsSide Burner Locating Your BUILT-IN Side BurnerGAS Instructions GAS Line LocationsBUILT-IN GAS Line Locations Test ConnectionsGAS Line Piping Typical Natural GAS Supply InstallationGeneral Specifications for Piping Connect GAS Supply Side Burner Lighting Instructions Lighting the Side BurnerOperating / Maintenance Manually Lighting the Side BurnerIgniter To ExtinguishSide Burner Maintenance Side Burner TroubleshootingProblem Check Cure Para SU Seguridad Peligros Y Advertencias PeligroAdvertencias Únicamente Unidades DE GAS Propano LicuadoGARANTÍA13 GarantíaAlmacenaje OperaciónDimensiones DE Corte DEL Empotramiento Instrucciones Para EL GASQuemador Lateral Ubicación DEL Quemador Lateral EmpotradoInstrucciones Para EL GAS Ubicaciones DE LA Línea DE GASUbicaciones DE LAS Líneas DE GAS Empotradas Pruebe LAS Conexiones16INSTRUCCIONES Para EL GAS Especificaciones Generales Para LA TuberíaConectar EL Suministro DE GAS Conexiones DE Suministro DE GAS Natural AL Quemador LateralPrueba DE LA Conexión DEL GAS Natural Instrucciones Para Encender EL Quemador Lateral PeligroEncendido DEL Quemador Lateral Operación /MANTENIMIENTO Encendido Manual DEL Quemador Lateral PeligroEncendedor Reemplace LAS Baterías DEL EncendedorMantenimiento DEL Quemador Lateral Resolución DE Problemas CON EL Quemador LateralProblema Revisar Remedio CES Accessoires Sont Vendus Separement Mises EN Garde Appareils a GAZ Propane UniquementGARANTIE23 GarantieStockage UtilisationDimensions Pour LE Decoupage DE LA Structure Encastree Instructions Relatives AU GAZLocalisation DU Bruleur Lateral Bruleur LateralInstructions Relatives AU GAZ Localisations DES Conduites DE GAZLocalisations DES Conduites DE GAZ Encastrees Test DES ConnexionsGeneralites Concernant LES Canalisations Installation D’ARRIVEE DE GAZ Naturel TypiqueCanalisations DE GAZ Test DES Raccords Raccordement DE L’ARRIVEE DE GAZInstructions Pour L’ALLUMAGE DU Bruleur Lateral Allumage DU Bruleur LateralUTILISATION/MAINTENANCE29 Allumage Manuel DU Bruleur LateralPour Eteindre AllumeurDepannage DU Bruleur Lateral Probleme Verification SolutionMaintenance DU Bruleur Lateral Page WEBER-STEPHEN Products CO