Weber 89795 manual Connect GAS Supply

Page 7

GAS INSTRUCTIONS

7

 

 

TEST CONNECTIONS

All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, or the Standard for Recreational Vehicles, ANSI A 119.2/NFPA 1192, and CSA Z240 RV Series, Recreational Vehicle Code, as applicable.

DANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for gas leaks. This will result in a fire or explosion which can cause serious bodily injury or death, and damage to property.

CONNECT GAS SUPPLY

1)Uncap the flare fitting from the optional side burner connection located at regulator.

Note: You must connect your side burner to a Weber® approved regulator (part number #62434) located at main gas supply. If you do not use a Weber® approved regulator the Warranty on the Summit® Built-In Side Burner will be voided. If you have any questions, contact Customer Service at 1-800-446-1071.

2)Connect the corrugated gas line to the side burner Connection.

TEST CONNECTIONS

All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of ANSI Z223.1/NFPA54.

DANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for gas leaks. This will result in a fire or explosion which can cause serious bodily injury or death, and damage to property.

WARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Note - All factory-made connections have been thoroughly checked for gas leaks.As a safety precaution however, you should recheck all fittings for leaks before using your Summit® Built-In side burner. Shipping and handling may loosen or damage a gas fitting.

You will need: a soap and water solution, and a rag or brush to apply it.

Turn on gas supply.

Check for leaks by wetting the connections with the soap and water solution and watch- ing for bubbles. If bubbles form or if a bubble grows, there is a leak.

Note - Since some leak test solutions, including soap and water, may be slightly cor- rosive, all connections should be rinsed with water after checking for leaks.

WARNING: Do not ignite burners when leak checking.

 

SIDE BURNER NG SUPPLY CONNECTIONS

1

Cap (Optional Side Burner)

 

 

2

Hard Piped Gas Supply

3

Regulator

4

To SIde Burner

aTop View

a.

1.

2.

3.

a.

2.

4.

3.

WWW.WEBER.COM®

Image 7
Contents #89795 Liquid Propane GAS Units only Wash hands after handling this productStorage WARRANTY3Warranty Operating GAS Supply TestingLocating Your BUILT-IN Side Burner BUILT-IN Structure Cutout DimensionsGAS Instructions Side BurnerTest Connections GAS InstructionsGAS Line Locations BUILT-IN GAS Line LocationsGeneral Specifications for Piping Typical Natural GAS Supply InstallationGAS Line Piping Connect GAS Supply Lighting the Side Burner Side Burner Lighting InstructionsTo Extinguish Operating / MaintenanceManually Lighting the Side Burner IgniterProblem Check Cure Side Burner TroubleshootingSide Burner Maintenance Para SU Seguridad Únicamente Unidades DE GAS Propano Licuado Peligros Y AdvertenciasPeligro AdvertenciasOperación GARANTÍA13Garantía AlmacenajeUbicación DEL Quemador Lateral Empotrado Dimensiones DE Corte DEL EmpotramientoInstrucciones Para EL GAS Quemador LateralPruebe LAS Conexiones Instrucciones Para EL GASUbicaciones DE LA Línea DE GAS Ubicaciones DE LAS Líneas DE GAS EmpotradasEspecificaciones Generales Para LA Tubería 16INSTRUCCIONES Para EL GASConexiones DE Suministro DE GAS Natural AL Quemador Lateral Conectar EL Suministro DE GASEncendido DEL Quemador Lateral Instrucciones Para Encender EL Quemador Lateral PeligroPrueba DE LA Conexión DEL GAS Natural Reemplace LAS Baterías DEL Encendedor Operación /MANTENIMIENTOEncendido Manual DEL Quemador Lateral Peligro EncendedorProblema Revisar Remedio Resolución DE Problemas CON EL Quemador LateralMantenimiento DEL Quemador Lateral CES Accessoires Sont Vendus Separement Appareils a GAZ Propane Uniquement Mises EN GardeUtilisation GARANTIE23Garantie StockageBruleur Lateral Dimensions Pour LE Decoupage DE LA Structure EncastreeInstructions Relatives AU GAZ Localisation DU Bruleur LateralTest DES Connexions Instructions Relatives AU GAZLocalisations DES Conduites DE GAZ Localisations DES Conduites DE GAZ EncastreesCanalisations DE GAZ Installation D’ARRIVEE DE GAZ Naturel TypiqueGeneralites Concernant LES Canalisations Raccordement DE L’ARRIVEE DE GAZ Test DES RaccordsAllumage DU Bruleur Lateral Instructions Pour L’ALLUMAGE DU Bruleur LateralAllumeur UTILISATION/MAINTENANCE29Allumage Manuel DU Bruleur Lateral Pour EteindreMaintenance DU Bruleur Lateral Probleme Verification SolutionDepannage DU Bruleur Lateral Page WEBER-STEPHEN Products CO