Frymaster Super Runner Series, Super Marathon Series manual Replacing the Operating Thermostat

Page 12

1.7.1 Replacing the Operating Thermostat (cont.)

6.First, loosen the capillary tube compression fitting until it slides freely on the capillary tube. Second, loosen the frypot pass-through nut until it slides freely on the capillary tube. Remove the capillary tube and bulb from the frypot.

7.Install the replacement thermostat capillary tube and bulb in the frypot. Apply a small amount of Loctite PST567 compound or equivalent to the threads of the frypot pass-through nut and screw the replacement thermostat securely into the frypot, being careful not to twist the capillary tube as the fitting is tightened. DO NOT tighten the capillary tube compression nut at this time.

8.Position the thermostat bulb in tube-mounted clamp and replace mounting hardware. Ensure probe bulb is properly positioned in the clamp (¼" from burner tube) and screws are properly tightened.

9.Tighten the capillary tube compression nut once the capillary tube is properly positioned. NOTE: Once the compression nut is tightened, the capillary tube cannot be repositioned. If a mistake in installation has been made, a new thermostat will have to be installed.

10.Mount the thermostat control to the mounting bracket using the screws removed in Step 4.

11.Connect the wires disconnected in Step 3 to the thermostat.

Compression Fitting

 

 

Thermostat Bulb

Capillary Tube

Frypot Fitting

 

Operating

 

Thermostat

 

12.Install the thermostat knob on thermostat control shaft. Check thermostat calibration and calibrate if the range is outside of the recommended ranges in section 1.4.

1-7

Image 12
Contents Hour Service Hotline Super Runner and Super Marathon SeriesMAY Page Iii Table of Contents Parts List Functional Description NON-CE Altitudes of 2000 feet or lessCE only Altitudes of 2000 feet or less Pilot Ignition System ThermostatsAccessing Fryers for Servicing Cleaning the Gas Valve Vent TubeCalibrating the Operating Thermostat Check Burner Manifold Pressure Adjusting the Pilot Flame Replacing Fryer ComponentsReplacing the Operating Thermostat Replacing the Operating Thermostat Replacing the High-Limit Thermostat Replacing the FrypotTroubleshooting and Problem Isolation Pilot FailuresComplete System Check System Resistance CheckAutomatic Pilot Dropout Check Pilot Fails to Light Improper Burner Functioning Filtration Problems Leaking Wiring Diagrams Current Production Units with Honeywell Gas Valve Non-CECurrent Production Units with Honeywell Gas Valve CE Current Production Units with Robertshaw Gas Valve After May UFF Filtration Wiring Diagram OptionalCabinetry Components, Single Fryers Channel, Base- Front & Rear Non-Filtration Single FryersSuff Base Components- SM Series With Suff Filtration Side Panel, LeftSide Panel, Right Door Assembly Components Panel, Outer Door- SM20G Assembly 106-2482SPCabinetry Components, Multi-Battery Frying Systems Base Channel, Front & Rear- SM220G, SM50G See .1 ForAdditional Single Fryer Base Channel Components Accessories Fluecap, SM20/20/50GDean Millivolt GAS Fryers Parts List Thermostat, Sunne Use 807-1692 for CE Frypot and Burner System Components 1 SM220 and SM20/20/~ SystemsFlue Assembly- SM20G SR Series, SM35G, SM40G and SM50G Systems Burner, Right- SR38G, SR42G, SM35G, SM40G Burner, Center- SR38G, SR42G, SM35G, SM40GBurner, Left- SR38G, SR42G, SM35G, SM40G Shield, Burner Heat- SR52G, SM5025 106-1742SPFlue Assembly- SR52G, SM50G Flue Assembly- SR38G106-0696SPFlue Assembly- SR42G 106-0954SPFlue Assembly- SM35G, SM40G3 SR62, SM60G and SM80G Systems SM80G ShownValve, Trailing Pilot- SM60G, SM80G, SR62G adjustment valve Frypot- M/S- SM80G Prior To 10/99 obsolete useFrypot- S/S- SM60G, SR62G Use 823-3511SP for SM160G Flue Assembly- SM80G Flue Assembly- SM60G, SR62GOil Drain Manifold Componets Oil Drain Manifold, Drain Flush and Drain Valve Components Drain Valve ComponentsPlace Over 2 3 Oil Drain Manifold, Drain Flush & Drain Valve Components Flush Oil Drain LineOil Return Manifold Components Oil Return Manifold Components Fryers with 1½ Drains810-0051 200-1143 809-0877 106-2568SP Not Illustrated Oil Return Manifold Components Fryers with 3 Drains Oil Return and Oil Flush Components Oil Return and Oil Flush Components Fryers with 1½ DrainsMicroswitch Bracket Assembly, Oil Return Oil Suction Start FittingOil Return and Oil Flush Components Fryers with 3 Drains Oil Suction Assembly Suction Manifold AssemblyUnder Fryer Filter UFF Components 1 SM50 and SM60 Series Fryers Except Ihop2 SM50 Series Fryers, Ihop UFF 50 with Filter Leaf 3 SM80 Series Fryers Single Under Fryer Filter Suff Components 1 SM50 Series Fryers2 SM60 and SM80 Series Fryers This page Intentionally Left Blank Service Hotline