CHAPTER 2: PARTS LIST

2.3Component Box Components and Related Components (CE and Domestic- cont.)

ITEM

PART #

1

826-2013

*810-2047

*210-1302

*200-1320

2810-2035

3200-1618

4200-3217

5200-3277

6200-3906

7810-2033

8810-1152

9106-1768SP

*106-1879

10200-5479

11810-2401

12810-1001

*200-1868

*807-3540

13

807-1999

*807-0800

14807-3580

15210-2786

16807-3516

*807-3560

*807-3680

*810-2046

17

807-1321

*

2747

*807-3592

*807-3750

*Not Illustrated

COMPONENT

Thermostat, Sunne (Use 807-1692 for CE)

Spring, Spacer- Thermostat Capillary Bulb

Clamp, Thermostat/High Limit Capillary Bulb

Mounting Bracket, Thermostat & High-Limit

Knob, Thermostat (Use 816-0139 for CE)

Box, Thermostat- Single

Cover, Thermostat Box- Single

Box, Thermostat- Dual (Used in 20/50 Combination Systems) Cover, Thermostat Box- Dual (Used in 20/50 Combination Systems) Thermopile (Use 807-3565 for CE)

Thermocouple (CE ONLY) (Use 812-1284 for Assembly) ECO Connector (Honeywell Valves Only- CE ONLY) ECO Connector (Robertshaw Valves Only- CE ONLY) Bracket, Pilot Thermocouple

Bracket, Thermopile

Piezo Ignitor (Trigger) (Wire Lead-807-3650) (Assembly-44970SP)

Piezo Bracket

Electrode, Piezo CE (Use 812-1532 for modified Electrode) Transformer, Dual Voltage CE- Filtration System (CE ONLY) Transformer, 120/24 VAC- Filtration System

Switch, Rocker- Manual Filter Power

Guard, Switch (Optional- For Item 10)

High-Limit Thermostat- Automatic Reset 435° F SM20/35,SR40/42 High-Limit Thermostat- Manual Reset 410° F (CE)

High-Limit Thermostat- Manual Reset 450° F Spring, Spacer- High Limit Capillary Bulb Fuse Holder, Buss

Fuse Holder, Slot-head—Safety (CE ONLY) Fuse 2A Slow-Blow (230V Systems)

Fuse 5A (120V Systems)

2-7

Image 30
Contents Hour Service Hotline Super Runner and Super Marathon SeriesMAY Page Iii Table of Contents Parts List Functional Description NON-CE Altitudes of 2000 feet or lessCE only Altitudes of 2000 feet or less Pilot Ignition System ThermostatsAccessing Fryers for Servicing Cleaning the Gas Valve Vent TubeCalibrating the Operating Thermostat Check Burner Manifold Pressure Adjusting the Pilot Flame Replacing Fryer ComponentsReplacing the Operating Thermostat Replacing the Operating Thermostat Replacing the High-Limit Thermostat Replacing the FrypotTroubleshooting and Problem Isolation Pilot FailuresComplete System Check System Resistance CheckAutomatic Pilot Dropout Check Pilot Fails to Light Improper Burner Functioning Filtration Problems Leaking Wiring Diagrams Current Production Units with Honeywell Gas Valve Non-CECurrent Production Units with Honeywell Gas Valve CE Current Production Units with Robertshaw Gas Valve After May UFF Filtration Wiring Diagram OptionalCabinetry Components, Single Fryers Channel, Base- Front & Rear Non-Filtration Single FryersSuff Base Components- SM Series With Suff Filtration Side Panel, LeftSide Panel, Right Door Assembly Components Panel, Outer Door- SM20G Assembly 106-2482SPCabinetry Components, Multi-Battery Frying Systems Base Channel, Front & Rear- SM220G, SM50G See .1 ForAdditional Single Fryer Base Channel Components Accessories Fluecap, SM20/20/50GDean Millivolt GAS Fryers Parts List Thermostat, Sunne Use 807-1692 for CE Frypot and Burner System Components 1 SM220 and SM20/20/~ SystemsFlue Assembly- SM20G SR Series, SM35G, SM40G and SM50G Systems Burner, Left- SR38G, SR42G, SM35G, SM40G Burner, Right- SR38G, SR42G, SM35G, SM40GBurner, Center- SR38G, SR42G, SM35G, SM40G Shield, Burner Heat- SR52G, SM50106-0696SPFlue Assembly- SR42G 25 106-1742SPFlue Assembly- SR52G, SM50GFlue Assembly- SR38G 106-0954SPFlue Assembly- SM35G, SM40G3 SR62, SM60G and SM80G Systems SM80G ShownValve, Trailing Pilot- SM60G, SM80G, SR62G adjustment valve Frypot- M/S- SM80G Prior To 10/99 obsolete useFrypot- S/S- SM60G, SR62G Use 823-3511SP for SM160G Flue Assembly- SM80G Flue Assembly- SM60G, SR62GOil Drain Manifold Componets Oil Drain Manifold, Drain Flush and Drain Valve Components Drain Valve ComponentsPlace Over 2 3 Oil Drain Manifold, Drain Flush & Drain Valve Components Flush Oil Drain LineOil Return Manifold Components Oil Return Manifold Components Fryers with 1½ Drains810-0051 200-1143 809-0877 106-2568SP Not Illustrated Oil Return Manifold Components Fryers with 3 Drains Oil Return and Oil Flush Components Oil Return and Oil Flush Components Fryers with 1½ DrainsMicroswitch Bracket Assembly, Oil Return Oil Suction Start FittingOil Return and Oil Flush Components Fryers with 3 Drains Oil Suction Assembly Suction Manifold AssemblyUnder Fryer Filter UFF Components 1 SM50 and SM60 Series Fryers Except Ihop2 SM50 Series Fryers, Ihop UFF 50 with Filter Leaf 3 SM80 Series Fryers Single Under Fryer Filter Suff Components 1 SM50 Series Fryers2 SM60 and SM80 Series Fryers This page Intentionally Left Blank Service Hotline