1.8.4 Filtration Problems (cont.)

3.Prior to reassembly, the inside housing must be clean and free of any sediment or debris. Failure to completely clean the inside housing and ring gear will cause gear binding after reassembly.

Incorrectly sized or installed paper will allow food particles and sediment to pass through and clog the suction tube on the bottom of the filter carriage. Particles large enough to block the suction tube may indicate that the crumb tray is not being used.

Pan blockage can also occur if shortening is left in the pan and allowed to solidify. Heater strips (if equipped) on the oil return plumbing are designed to prevent solidification of shortening left in the plumbing. Heater strips will not melt or prevent solidification of shortening in the pan.

Blockage removal can be accomplished by forcing the item out with an auger or drain snake. Compressed air or other pressurized gases should not be used to force out the blockage.

The electronics of the SUFF/UFF filtration systems are simple and straightforward. Microswitches, attached to handles for each vat and wired in parallel, provide the 24 VAC required to activate the pump relay coil when the handles are moved to the ON position. The activated pump relay coil pulls in the pump motor switch, supplying power to the pump motor.

Filter systems equipped with oil-return heaters are wired into the 120 VAC source, which remain energized as long as the unit is plugged in.

1.8.5 Leaking

Leakage of the frypot usually will be due to improperly sealed high-limits, thermostats, or drain fittings. When installed or replaced, each of these components must be sealed with Loctite PST567 sealant or equivalent to prevent leakage. In very rare cases, a leak may develop along one of the welded edges of the frypot. When this occurs, the frypot must be replaced.

If the sides and/or ends of the frypot are coated with oil, the most likely cause is spillage over the top of the frypot rather than leakage.

Frypot locations (indicated by arrows) where potential leaks could occur.

1-14

Image 19
Contents Super Runner and Super Marathon Series Hour Service HotlineMAY Page Iii Table of Contents Parts List NON-CE Altitudes of 2000 feet or less Functional DescriptionCE only Altitudes of 2000 feet or less Thermostats Pilot Ignition SystemCleaning the Gas Valve Vent Tube Accessing Fryers for ServicingCalibrating the Operating Thermostat Check Burner Manifold Pressure Replacing Fryer Components Adjusting the Pilot FlameReplacing the Operating Thermostat Replacing the Operating Thermostat Replacing the Frypot Replacing the High-Limit ThermostatPilot Failures Troubleshooting and Problem IsolationSystem Resistance Check Complete System CheckAutomatic Pilot Dropout Check Pilot Fails to Light Improper Burner Functioning Filtration Problems Leaking Current Production Units with Honeywell Gas Valve Non-CE Wiring DiagramsCurrent Production Units with Honeywell Gas Valve CE Current Production Units with Robertshaw Gas Valve After May Optional UFF Filtration Wiring DiagramChannel, Base- Front & Rear Non-Filtration Single Fryers Cabinetry Components, Single FryersSide Panel, Left Suff Base Components- SM Series With Suff FiltrationSide Panel, Right Panel, Outer Door- SM20G Assembly 106-2482SP Door Assembly ComponentsBase Channel, Front & Rear- SM220G, SM50G See .1 For Cabinetry Components, Multi-Battery Frying SystemsAdditional Single Fryer Base Channel Components Fluecap, SM20/20/50G AccessoriesDean Millivolt GAS Fryers Parts List Thermostat, Sunne Use 807-1692 for CE 1 SM220 and SM20/20/~ Systems Frypot and Burner System ComponentsFlue Assembly- SM20G SR Series, SM35G, SM40G and SM50G Systems Shield, Burner Heat- SR52G, SM50 Burner, Right- SR38G, SR42G, SM35G, SM40GBurner, Center- SR38G, SR42G, SM35G, SM40G Burner, Left- SR38G, SR42G, SM35G, SM40G106-0954SPFlue Assembly- SM35G, SM40G 25 106-1742SPFlue Assembly- SR52G, SM50GFlue Assembly- SR38G 106-0696SPFlue Assembly- SR42GSM80G Shown 3 SR62, SM60G and SM80G SystemsFrypot- M/S- SM80G Prior To 10/99 obsolete use Valve, Trailing Pilot- SM60G, SM80G, SR62G adjustment valveFrypot- S/S- SM60G, SR62G Use 823-3511SP for SM160G Flue Assembly- SM60G, SR62G Flue Assembly- SM80GOil Drain Manifold Componets Drain Valve Components Oil Drain Manifold, Drain Flush and Drain Valve ComponentsPlace Over Flush Oil Drain Line 2 3 Oil Drain Manifold, Drain Flush & Drain Valve ComponentsOil Return Manifold Components Fryers with 1½ Drains Oil Return Manifold Components810-0051 200-1143 809-0877 106-2568SP Not Illustrated Oil Return Manifold Components Fryers with 3 Drains Oil Return and Oil Flush Components Fryers with 1½ Drains Oil Return and Oil Flush ComponentsOil Suction Start Fitting Microswitch Bracket Assembly, Oil ReturnOil Return and Oil Flush Components Fryers with 3 Drains Suction Manifold Assembly Oil Suction Assembly1 SM50 and SM60 Series Fryers Except Ihop Under Fryer Filter UFF Components2 SM50 Series Fryers, Ihop UFF 50 with Filter Leaf 3 SM80 Series Fryers 1 SM50 Series Fryers Single Under Fryer Filter Suff Components2 SM60 and SM80 Series Fryers This page Intentionally Left Blank Service Hotline