2.1General Installation Requirements

Proper installation is essential for the safe, efficient, trouble-free operation of this appliance.

Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6 of this manual, should perform all installation and service on Frymaster equipment.

Failure to use qualified, licensed, and/or authorized installation or service personnel (as defined in Section 1.6 of this manual) to install or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel.

Where conflicts exist between instructions and information in this manual and local or national codes or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed.

Service may be obtained by contacting your local Frymaster Factory Authorized Servicer.

NOTICE

All fryers shipped without factory supplied cords and plug assemblies must be hardwired using flexible conduit to the terminal block located on the rear of the fryer. These fryers should be wired to NEC specifications. Hardwired units must include installation of restraint devices.

DANGER

Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit. A restraint kit is provided with the fryer. If the restraint kit is missing contact your local KES.

NOTICE

If this equipment is wired directly into the electrical power supply, a means for disconnection from the supply having a contact separation of at least 3-mm in all poles must be incorporated in the fixed wiring.

NOTICE

This equipment must be positioned so that the plug is accessible unless other means for disconnection from the power supply (e.g., a circuit breaker) is provided.

NOTICE

If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less than 167°F (75°C).

NOTICE

If the electrical power supply cord is damaged, it must be replaced by a Frymaster Dean Factory Authorized Service technician or a similarly qualified person in order to avoid a hazard.

2-1

Image 9
Contents Oil Conserving Fryer OCF30 Electric Series Fryers Hour Service HotlineCanada Page Table of Contents Table of Contents Operator Troubleshooting Computer Information European Community CE Specific InformationDefinitions Service Information Shipping Damage Claim ProcedureGeneral Installation Requirements OCF30 II Series Electric Fryers Installation InstructionsClearance and Ventilation Australian Requirements Power RequirementsPage Finding Your WAY around the OCF30 Series Electric Fryer OCF30 Series Electric Fryer Operating InstructionsSetup Equipment Setup and Shutdown ProceduresInstall the Oil Reservoir Optional Oil Attendant Automatic Top-OffPrepare the System for Use Routine Oil Changes OCF30 Series Electric Fryers Filtration Instructions Preparation for Use with the Magnasol Filter Assembly Filtration Filter Pump Reset Switch Cleaning Draining and Disposing of Waste Oil ReassemblyPage OCF30 Series Electric Fryers Preventative Maintenance Inspect Fryer and Accessories for Damage- DailyClean Inside and Outside of the Fryer Cabinet Daily Page Check the Controller Set Point Accuracy Annual/Periodic System InspectionFryer Built-In Filtration System Introduction OCF30 Series Electric Fryers Operator TroubleshootingError Messages and Display Problems Troubleshooting Controller and Heating ProblemsOr LOw temp Basket Lift ProblemsAuto Top-Off Problems Filtration ProblemsExplanation Error Log Codes For 3000 Controller OnlyPage OCF30 Series Simplified Wiring with 3000 Controller OCF30 Series Electric Fryers Wiring DiagramsComponent Wiring with 3000 controller Domestic Component Wiring with CM3.5 controller Domestic Component Wiring with CM3.5 Controller CE Component Wiring with CM3.5 Controller CSA Contactor Box Delta Configuration Contactor Box WYE Configuration Assembled melter is shown in position Appendix B Solid Shortening Melter Use OCF30 Series Electric FryerBulk Oil Systems OCF30 Series Electric Fryer Appendix C Bulk OIL InstructionsDo not add HOT or Used oil to a JIB Filling the JIBDispose of Waste Oil Fill Vat from Bulk Tank Service Hotline