RE SERIES MARINE E4 ELECTRIC FRYERS
CHAPTER 7: SERVICE PROCEDURES
7.1General
Before performing any maintenance on this equipment, disconnect the fryer from the electrical power supply.
When electrical wires are disconnected, it is recommended that they be marked in such a way as to facilitate
7.2Replacing a Remote Digital Controller
1.Unplug all power cords.
2.Unplug the
3.Remove the mounting screws.
4.Reassemble in reverse order to complete the replacement and return the fryer to service.
7.3Replacing Component Box Components
1.Disconnect the fryer from the electrical power supply.
2.The front panel bezel is held in place by tabs at the top and bottom. Slide the metal bezel up to disengage the lower tabs. Then slide the bezel down to disengage the upper tabs.
3.Remove the two screws from the upper corners of the front panel bezel and allow the front panel bezel to swing down.
4.Remove the front panel bezel assembly by lifting it from the hinge slots in the panel bezel frame.
5.Disconnect the wiring from the component to be replaced, being sure to make a note of where each wire was connected.
6.Dismount the component to be replaced and install the new component, being sure that any required spacers, insulation, washers, etc. are in place.
NOTE: If more room to work is required, the control panel frame assembly may be removed by removing the hex head screws that secure it to the fryer cabinet (see illustration on the following page). If this option is chosen, all front panel assemblies must be removed per steps