DANGER
All wiring connections for this appliance must be made in accordance with the wiring diagram(s) furnished with the appliance. Refer to the wiring diagram(s) affixed to the inside of the appliance door when installing or servicing this equipment.
DANGER
The appliance area must be kept free and clear of combustible material at all times.
WARNING
Do not block the area around the base or under the fryers.
All installation and service on FRYMASTER equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel.
Service may be obtained by contacting a local Frymaster DEAN Factory Authorized Service Center.
In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the power switch OFF. Do not attempt to start the fryer(s) until power is restored.
A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible construction. A minimum of 24 inches (61cm) should be provided at the front of the equipment for servicing and proper operation.
Connections should be made by means of an approved,
2.2Power Requirements
Use copper wire ONLY, suitable for at least 167°F (75°C)
MODEL | VOLTAGE | PHASE | WIRE | MINIMUM WIRE | AMPS | |
SIZE |
| |||||
SERVICE |
| (per leg) | ||||
|
|
| AWG | mm | ||
|
|
|
|
| ||
FPRE117 | 440 | 3 | 3 | 6 | (4.11) | 23 |
FPRE117 | 480 | 3 | 3 | 6 | (4.11) | 21 |
FPRE217(Per Vat) | 440 | 3 | 3 | 6 | (4.11) | 23 |
FPRE217 (Per Vat) | 480 | 3 | 3 | 6 | (4.11) | 21 |
RE Series Marine electric fryers are equipped with a filter system that requires a separate 120VAC or 220VAC depending on configuration,
NOTICE
If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less than 167°F (75°C).
DANGER
This appliance must be connected to a power supply having the same voltage and phase as specified on the rating plate located on the inside of the appliance door.